Troubleshooting guide
13.2

Malfunction indications appearing on the display

Display message
Malfunction description
Power Failure!!
Prolonged interruption of electrical power
The appliance starts up again automatically and indicates the highest recorded
temperatures
Door open
Door open
this message appears few minutes from the door opening
TriMode open
Drawer open
this message appears few minutes from the drawer opening
Cellar too warm
Cellar (Wine Cellar) compartment too warm
See the troubleshooting guide
Cellar too cold
Cellar (Wine Cellar) compartment too cold
Wait 12 hours. If the problem persists, contact Customer Care
Riserva too warm
Cantina (Riserva) compartment too warm
See the troubleshooting guide
Riserva too cold
Cantina (Riserva) compartment too warm
Wait 12 hours. If the problem persists, contact Customer Care
Fridge too warm
TriMode compartment (refrigerator mode) too warm
See the troubleshooting guide
Fridge too cold
TriMode compartment (refrigerator mode) too cold
Wait 12 hours. If the problem persists, contact Customer Care
Fresco too warm
TriMode compartment (cooler mode) too warm
See the troubleshooting guide
Fresco too cold
TriMode compartment (cooler mode) too cold
Wait 12 hours. If the problem persists, contact Customer Care
TriMode too warm
TriMode compartment (freezer mode) too warm
See the troubleshooting guide
TriMode too cold
TriMode compartment (freezer mode) too cold
Wait 12 hours. If the problem persists, contact Customer Care
Error Code...
Functional problems
call Customer Care who may help you to salve the problem or put you in contact
with the nearest Service Agent