Maintenance
EN
Replacing / Cleaning thermostatic capsule
1. Observe the Important Safety Note.
2. Take the steam trap out of the pipe.
3. Unscrew upper body part from lower body part.
4. Clean thermostatic capsule.
5. Replace thermostatic capsule in case of visible signs of wear or damage.
6. Press new or cleaned thermostatic capsule onto the lower body part until it snaps
into place.
7. Screw body parts together and tighten with a torque of 100 Nm.