3.5
After use
WARNING
!
Do not doff the facepiece unless you are decontaminated and
in a safe environment.
Doff the facepiece as follows:
1. Remove canister, powered air-purifying respirator, self-contained
breathing apparatus, or air line breathing apparatus.
2. Pull the adjuster buckles of the neck straps forward with your
thumb and loosen the straps (see Figure F on page 3).
3. Pull the facepiece away from your face over the head.
4. Dispose of the canister according to national guidelines.
4
Maintenance
4.1
Maintenance table
The following details are manufacturer recommendations. Observe
national guidelines, too.
Type of work to be
performed
Visually check the facepiece
Clean and disinfect the
facepiece
Check correct function and
leak-tightness
Dräger X-plore 6000
X
1)
X
X
2)
X
X
(Use Instructions for NIOSH-approved full facepieces)
Type of work to be
performed
Replace exhalation valve
disc
Replace speech diaphragm
and O-ring
1)
valid for airtight packed facepieces, otherwise every 6 months
2)
for airtight packed facepieces every 2 years
Maintenance
X
X
79