Problem
Drive is not functioning.
Transmission control
light is on.
Drive is not running ,
LED is not illuminated.
Automatic control com-
mands are not carried
out.
The system does not au-
tomatically extend when
should the sliding switch
be set to "S".
The system does not
extend in response to a
manual command when
the sliding switch is set
to "H" or "S".
General conformity declaration
Becker-Antriebe GmbH hereby declares that the device Centronic SensorCon-
trol SC861 complies with the basic requirements and other relevant regulations
of the EC Directive R&TTE 1999/5/EC.
For use in the following countries: EU, CH, NO, IS, LI
Subject to technical changes without notice.
What to do if ...?
Cause
1. Receiver is outside
of the radio operating
range.
2. The SC861 has not
been programmed into
the receiver.
Energy storage is
empty.
The sliding switch of the
hand-held/wall trans-
mitter is set to manual
mode "H".
1. The sunlight thresh-
old value has not been
reached.
2. The wind thresh-
old value is has been
exceeded.
The wind threshold
value of the transmitter
has been exceeded.
Remedy
1. Reduce the distance
to the receiver.
2. Programme the
SC861.
SC861 has to be char-
ged by sunlight.
Adjust the sliding switch
of the hand-held/wall
transmitter to automatic
mode "S".
1. Adjust sunlight
threshold value using
the transmitter.
2. Wait until wind
abates.
Wait until wind abates.