ActSafe T1-16 Manuel Utilisateur page 73

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLE SHOOTNG GUIDE
The ascender switches off when newly recharged
PROBABLE CAUSE
The charging process is incomplete
due to oxidation on the pins.
The charger is broken/damaged.
The battery is too cold.
The battery is flat.
Ascender operates at very low speed
PROBABLE CAUSE
The battery is running low, only a few
percent of the capacity is remaining.
The ascender is over loaded.
The battery is to cold.
The grab on the rope is poor, the rope slips
PROBABLE CAUSE
Rope connected incorrectly.
The rope is not suitable
for the ascender.
The rope grab is worn.
The lifting capacity is notably weak
PROBABLE CAUSE
The charging process is incomplete
due to oxidation on the pins.
The battery is damaged.
The battery is too cold.
34
REMEDY
Clean the pins according to manual and recharge the battery.
Repair/replace the charger, contact ActSafe
or an approved distributor.
Let the ascender heat up by operating with load at low speed.
The ascender is in need of repair and service,
contact ActSafe or an approved distributor.
REMEDY
Recharge the battery.
Lighten the load.
Let the battery heat up by operation with load at low speed.
REMEDY
Reconnect the rope.
Change the rope.
The ascender is in need of repair and service,
contact ActSafe or an approved distributor.
REMEDY
Clean the pins according to manual and recharge the battery.
The ascender is in need of repair and service, contact ActSafe
or an approved distributor.
Let the ascender heat up by operating with load at low speed.
© Copyright ActSafe Systems AB

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour ActSafe T1-16