Users of this product must have been cer-
tified or have undergone proper approved
training either by ActSafe Systems AB or by
ActSafe approved distributors.
Ascender safety
The ascender must not be used:
• For anything other than that for which
it has been designed.
• In an explosive environment.
• If modified in any way by anyone other
than ActSafe Systems AB.
• After a free fall from a height more than
1 meter against any hard surface.
• If subjected to a dynamic load as it is
designed to work in static systems only.
• If filled with water or if you suspect risk
of a leakage.
• If subjected to mis-use in any way those
parts or components may have been
damaged.
• In combination with other than ActSafe
original battery charger.
• In combination with damaged or
modified battery charger
General safety measures
• Draw up a risk analysis and a minimum
of 2 separate rescue plans.
• Make suitable rescue equipment
available.
• Check all components in the system.
6
DANGER
Read this chapter carefully and make sure
you understand its contents.
Use only original spare parts / material
recommended by ActSafe Systems AB.
If opened and closed by anyone other than
competent personnel it may not be water-
tight. If the inside of the ascender is filled with
water the battery can generate flammable
gas, thus causing a risk of explosion.
Other battery chargers may damage the
battery and may cause development of toxic
gases or in worst-case scenarios cause an
explosion.
If unclear of the condition of the ascen-
der, it must be inspected and approved by
ActSafe Systems AB or an ActSafe approved
distributor before use.
The ActSafe Ascender and its equipment
must be checked before and after every
use and must be subject to at least one
inspection per year (national regulations
may require more frequent inspections).
RECOMMENDATION
Plan for rescue when rigging the rope system.
The area of risk under someone working at
height is within a radius of 2/3 of the height and
larger due to strong wind. Other persons must
keep away from the area of risk.
Always secure tools and equipment.