Main components
L
C
D
UN003603-IT
A) Head
B) Pump body
C) Crankshaft
D) Connecting-rod
E) Intake valve
Intended uses
The pump is designed and built for incorporation in ma-
chinery and plant systems (construction machinery, ma-
chinery used to strip paint from building walls, machin-
ery for washing raw materials, finished products, road
washing etc.).
Misuses
Do not put the pump into service until the plant or ma-
chinery in which it is incorporated has been declared
compliant with the relevant national and local legal re-
quirements.
Do not use the pump in a potentially explosive atmos-
phere.
Do not use the pump for flammable, toxic or corrosive
liquids, or those with unsuitable density. Do not take in
English language
TECHNICAL INFORMATION
H
G
A
F) Delivery valve
G) Piston
H) Piston guide
L) Guide piston
The pump must be used in a manner appropriate to its
technical data (see "Technical Data"), and must not be
modified or improperly used.
liquids at temperatures higher than those specified in
the technical data.
Do not use the pump for the supply of drinking water.
Do not use the pump on products for human consump-
tion.
Do not use the pump on pharmaceutical products.
25
2
B
Use and Installation