Connection To An Auxiliary Pump (Force-Feed) - Annovi Reverberi RTX 30.300 Notice D'utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The connection must comply with the recommenda-
tions provided.
1) The pump must be installed in a position below the
tank intake (with positive head).
2) The tank must have baffles to prevent water splashes
and its capacity must be at least 10 times greater than
the pump's rated displacement.

Connection to an auxiliary pump (force-feed)

The connection must comply with the recommenda-
tions provided.
1) The auxiliary pump must have a flow rate twice the
high pressure pump's rated delivery rate and an oper-
ating pressure of 2 - 3 bar.
A) Tank
B) Intake filter
C) Auxiliary pump
D) High pressure
pump
E) Pressure gauge
F) Pressure damper
G) Relief valve (by-pass
valve)
H) Dump pipeline
L) Nozzle
M) Shut-off valve
English language
INSTALLATION INSTRUCTIONS
A
B
C
UN003594-IT
3) The vacuum measured directly at the pump intake
port must not exceed 0.1 bar and the water tempera-
ture must not be above 40 °C.
4) Adopt all the precautions described in the "General
guidelines on water connections" section.
2) Adopt all the precautions described in the "General
guidelines on water connections" section.
The following is a simplified illustration of the layout for
connection of the pump to an auxiliary pump.
D
33
G
F
E
Use and Installation
5
L

Publicité

Table des Matières
loading

Table des Matières