Table of lubricants
The pump is delivered complete with oil, with the char-
acteristics stated on the data plate.
When changing the oil, use an oil suitable for conditions
in the operating environment (see recommendations
Oil used for filling in factory
SAE 30
Inspecting the pump mounting
Check that the pump's fixing screws have not become loose.
If necessary, tighten them with the driving torque stated in the installation design.
Inspecting the connections and pipes
- Inspect the connections for leaks.
Leaks can normally be dealt with by tightening the con-
nections properly.
If leaks from the intake pipeline connections are noticed,
the seals must be repaired.
Inspecting the filter
- Inspect the filter cartridge.
If the filter cartridge is fouled or damaged, refer to the filter manufacturer's instructions for details of how to restore
the filter cartridge to its original filtering condition.
Checking the oil level
- Check the oil with the pump level and cold.
- Check the amount of oil through the level gauge (A).
- If necessary, top up with oil with the characteristics
specified in the "Comparison table of lubricants".
To top up with oil proceed as described below.
1) Unscrew the plug (B) and pour oil in until it is half-
way up the level gauge (A).
2) Screw on the plug (B).
English language
MAINTENANCE INSTRUCTIONS
Comparison table of lubricants
AGIP
DIESEL GAMMA 30
SUPER DIESEL 15W40
provided in the annexes and see "Environmental operat-
ing limits").
The correct lubricating oil viscosity depends on the ex-
ternal temperature.
MOBIL
DELVAC
SUPER 1400 15W40
- Inspect the hoses.
If the pipes show signs of aging, breakage, swelling, rub-
bing, etc., they must be replaced.
UN003599-IT
37
7
Use and Installation