6.3 Maintaining the protection class

The mobile receptacle combinations can be equipped on a
country-specific basis with different attached receptacles,
and they can be designed in different protection classes
(e.g. IP 44 or IP 67).
To maintain the protection class of the device, only electri-
cal consumers of the same protection class design must be
combined and operated with the receptacle combination,
(example: Connect an IP 67 plug of a consumer to an IP 67
receptacle of the receptacle combination).
Information on the protection class of your receptacle
combination can be found in the "Technical Data" chapter
or on the rating plate of the device.
• Before use, check which protection class design
corresponds to the receptacle combination and the
consumers that will be connected.
• Connect consumers with the same protection class and
a suitable plug device to the device in order to avoid
reducing the effect of the protection class.
If a plug of protection class IP 44 is inserted into a
receptacle combination of protection class IP 67, the
receptacle combination only meets the requirements
of protection class IP 44!
Consequence: limited protection function!
Pay particular attention with IP 44 protection class
devices and when using the device outdoors.

6.4 Connecting consumers

Connecting a consumer is described using the DELTA-BOX
in protection class IP 44 and IP 67 design as the example.
The procedure is comparable for device variants.
Risk of sustaining injury due to unintentional start-
-up of electrical consumers
Electrical consumers (e.g. drill) that are already switched
on via their own On/Off switch and that are connected
to the receptacle combination can start up autonomously
and cause injuries.
• Only switch an electrical consumer off via its own
On/Off switch before connecting it to the receptacle
combination.
6.4.1 Connecting consumers to the device in protec-
tion class IP 44
• Open the hinged lid of the socket and completely insert
the plug of the electrical consumer.
6.4.2 Connecting consumers on the device in protec-
tion class IP 67
4
3
2
Connecting consumers (example: DELTA-BOX)
• Open the closed hinged lid (1) by turning it counter-
clockwise.
• Open the hinged lid of the socket and completely insert
the plug (2) of the electrical consumer.
• Tighten the bayonet ring (3) of the plug at the socket
(4) by turning it clockwise (so that the protection class
requirements are met).
• Switch on the electrical consumer.