3. Residual Risks
3.1 Danger due to unsuitable ambient con-
ditions
Danger of injury due to unsuitable ambient condi-
tions
Use of the device under unsuitable ambient conditions
can result in device damage, which in turn can cause inju-
ry through electric shock.
• Only use the device under suitable ambient conditions to
prevent the risk of an electric shock.
Ö
Please refer to the "Technical Data" chapter
3.2 Danger due to a missing fuse
Danger due to an unsuitable or missing fuse
When using a device outdoors with unsuitable or missing
fusing via a residual current device, injuries due to electric
shock can occur.
• Only use the device outdoors if the device or the
supplying socket is fused via a suitable residual current
device.
• In case of doubt, consult a qualified electrician.
3.3 Fire hazard due to heat accumulation
Risk of sustaining injury due to fire
Heat may build up within the receptacle combination if
the device is covered by an object; this can cause a fire.
• Never cover the device.
• Do not put objects on the device.
6
Warning
Warning
Warning
3.4 Danger due to condensed water
The formation of condensation may occur within the recep-
tacle combination (especially with IP 67 protection class)
due to temperature fluctuations or intense solar radiation.
Material damage due to condensed water
Condensation may occur on the inside of the device in
the case of unfavourable ambient conditions. This may
cause damage to the device.
• Only operate the device under suitable ambient
conditions.
Ö
Please refer to the "Technical Data" chapter
• Use diaphragm cable glands for device ventilation
purposes.
4. Device Structure
Depending on the respective version, the device is
equipped with different components.
These may vary in terms of appearance, function, and
operation.
The main characteristics are described in the follow-
ing chapters of these instructions.
Further information on the devices and accessories
can be found in the current MENNEKES product cata-
logue or online under www.MENNEKES.de.
Attention