4 Technical data
Right of technical changes reserved.
Power tool
Rated voltage (DC
en
voltage)
Weight in accord-
ance with EPTA
procedure 01/2003
Dimensions (L x W
x H)
Rated speed under
no load
Impact speed
Torque
Standard screws
High-strength
screws
Chuck
Speed control
Forward / reverse
Deep discharge
protection
NOTE
Noise information (measured in accordance with EN 60745-1):
Power tool
Typical A-weighted
sound power level
Typical A-weighted
emission sound
pressure level
Uncertainty for the
given sound level
NOTE
The vibration emission level given in this information sheet has
been measured in accordance with a standardized test given in EN
60745 and may be used to compare one tool with another. It may
be used for a preliminary assessment of exposure. The declared
vibration emission level represents the main applications of the
tool. However if the tool is used for different applications, with
different accessories or poorly maintained, the vibration emission
may differ. This may significantly increase the exposure level over
the total working period. An estimation of the level of exposure
to vibration should also take into account the times when the tool
is switched off or when it is running but not actually doing the
job. This may significantly reduce the exposure level over the total
working period. Identify additional safety measures to protect the
operator from the effects of vibration such as: maintain the tool
and the accessories, keep the hands warm, organization of work
patterns.
Additional information in accordance with EN 60745
Triaxial vibration values (vibra-
tion vector sum)
Impact driving of fasteners of
maximum size for the power
tool ½", a
h
Impact driving of fasteners of
maximum size for the power
tool ¾", a
h
Uncertainty (K)
Battery
Rated voltage
4
Printed: 29.11.2013 | Doc-Nr: PUB / 5070699 / 000 / 03
SIW 22TA ½"
21.6 V
3 kg
232 mm x 94 mm x
258 mm
0...2,000/min
Max. 2,500/min
450 Nm
M12 M24
M8 M16
½" square drive
Electronic, by way
of the control
switch
Electronic switch
with interlock to
prevent switching
while running
Yes
SIW 22TA ½"
108 dB (A)
97 dB (A)
3 dB (A)
Measured in accordance with
EN 6074522
14.5 m/s²
14.2 m/s²
1.5 m/s²
B 22/3.3
LiIon
21.6 V
SIW 22TA ¾"
21.6 V
3.2 kg
251 mm x 94 mm x
258 mm
0...2,000/min
Max. 2,500/min
450 Nm
M12 M24
M8 M16
¾" square drive
with locking pin
Electronic, by way
of the control
switch
Electronic switch
with interlock to
prevent switching
while running
Yes
SIW 22TA ¾"
111 dB (A)
100 dB (A)
3 dB (A)
B 22/2.6
LiIon
21.6 V
B 22/1.6
LiIon
21.6 V