Technical Data
Mains voltage / frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Maximum flow rate
Maximum head
Maximum depth of Maximum depth
of immersion
Power cable H05 RNF
Weight
Maximum dimension of pumped
solid particles
Maximum temperature of the pumped fluid 35° C
Maximum number of starts per hour
Minimum priming level (A)*
Minimum suction level (B)*
Connection level (C)*
Stop level (D)*
Sound pressure level (Lpa) equal to or less than 70 dB(A)
Sound emission values obtained in conformity with the EN 12639 standard
(*) These data refer to Fig. 1. Measurements are expressed in millimetres.
The minimum priming level corresponds to a condition in which the delivery mouth is completely submersed.
(See Fig. 1 - Reference A)
The pumps of this series are not suitable for table fountains or aquariums. If these pumps are used in continuous mode
for ponds with fish, it is necessary to check them at regular intervals of 6 months (if the water contains aggressive
substances). It is also advisable to check the maximum dimension of particles recommended for the pump and take
the necessary measures to prevent the fish from being sucked into the pump.
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
DANGER
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
DANGER
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Use the handle provided to transport or lift the pump.
To use the pump in permanent installations with rigid pipes, to install a check valve to avoid the fluid being re-circulated
once the pump is stopped. The installation of a quick closing fitting in a convenient position facilitates cleaning and
maintenance operations.
The dimensions of the collection container should reduce to the minimum the number of starts per hour (see LIMITATIONS
- Technical data).
To use the pump for temporary applications, install a flexible pipe and connect it to the pump using a pipe holder. To
immerse the pump, use a rope and fix it to the handle.
FLOTEC VIPVORT, FP14 KVX, FP7 KV pumps have a pre-set floating switch. To change the setting, it is necessary
to increase or reduce the length of the floating switch cable by sliding it in the slot on the handle (See Fig. 1).
WARNING
WARNING
The pumps used in ponds, small lakes, fountains or similar installations or close to them should have a cut-out switch.
Contact a specialised electrician.
6
VIPVORT 130/5A
230 V ~ 50 Hz
370 Watt
IP 68 / F
41,90 mm (1"1/4 M) 41,90 mm (1"1/4 M) 41,90 mm (1"1/4 M) 41,90 mm (1"1/4 M)
7.800 l/h
5 m
7 m
10 m
3,9 Kg
25 mm
30
150 mm
30 mm
330 mm
150 mm
When installing, please ensure electropump is disconnected from
electrical supply. Pumps in this series are not suitable for use in a
swimming pool and the relevant cleaning and servicing operations.
To prevent possible injuries to people, avoid inserting hands into the mouth of the
pump if this is connected to the mains.
Verify that the floating switch stops the pump as soon as the minimum level is reached.
Make sure that the floating switch is free to move.
GB
VIPVORT 180/6A
FP14KVX
230 V ~ 50 Hz
230 V ~ 50 Hz 230 V ~ 50 Hz
480 Watt
600 Watt
IP 68 / F
IPX8 / B
10.800 l/h
14.000 l/h
6 m
8 m
7 m
5 m
10 m
10 m
4,2 Kg
5 Kg
25 mm
22 mm
35° C
35° C
30
30
150 mm
94 mm
30 mm
37 mm
330 mm
370 mm
150 mm
190 mm
2
FP7KV
350 Watt
IP68 / F
7.800 l/h
5 m
7 m
10 m
2,9 Kg
25 mm
35° C
30
150 mm
30 mm
330 mm
150 mm
(see also Fig. 7 and 8)