ATT Nussbaum SMART LIFT 2.30 Manuel D'exploitation page 118

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8.7.2 Selection the Liebig anchor with floor cover (screed, tiles)
(valid 2.30 SL, 2.35 SL, 2.40 SL)
Hole diameter 22 mm in the baseplate
Liebig anchor
Anchor type
Drill depth (mm)
Min. anchoring depth (mm)
Concrete thickness (mm)
Drill diameter (mm)
Component thickness (mm) e + f
Concrete quality
Number of anchors (pc.)
Torque of the anchors
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the details in the
foundation plans.
Similar value anchors and other known brands of anchor manufacturers can be used when considering
the conditions.
(1) Description of normal reinforcement:
A normal reinforcement is present if the axis separation in the area of the anchor with a rod diameter of
≥ 10 mm is 150 mm, or for a rod diameter of ≤ 10 mm is 100 mm.
118
BM12-20/80/65
a
100
b
80
c
min. 160*
d
20
40 – 65
Min. C20/25 normal reinforcement
Depending on the lift type
70 Nm
BM12-20/80/100
100
80
min. 160*
20
65 – 100
1
70 Nm
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL_V3.1_DE-EN-FR-ES-IT
BM12-20/80/140
100
80
min. 160*
20
100 – 140
70 Nm

Publicité

Table des Matières
loading

Table des Matières