Assembly and Operating Instructions
Light Sensor
Function of the SC43
With.the.SC43,.you.can.provide.your.plants.and.furniture.with.far.better.protec-
tion.from.the.sun's.harmful.rays.
The.SC43.should.always.be.attached.in.such.as.way.that.it.detects.exposure.
to. strong. sunlight. as. early. as. possible.. If. the. programmed. sunlight. setting. is.
exceeded,.SUN.will.appear.in.the.display..The.roller.shutters.or.the.blinds.auto-
matically.move.down.into.the.intermediate.position.or.as.far.as.the.SC43,.stop.
and.expose.the.SC43.which.is.then.ready.for.operation.
Shade Function:
If.the.light.setting.is.exceeded.for.more.than.3.minutes.->.roller.shutter.closes.
If.the.light.setting.is.below.the.light.setting.for.more.than.15.minutes.->.roller.
shutter.opens..
SUN
The.critical.value.is.pre-set.at.06.
The.sunshade.function.is.not.activated.if.the.setting.is.--..The.brightness.set-
tings.range.from.01.(very.overcast).to.15.(direct.sunlight).
The.display.shows.the.current.sunlight.setting.and.the.new.setting.to.be.made..
The.new.setting.to.be.made.flashes.
Twilight function:
If. the. twilight. setting. has. not. been. reached. after. 1:00. hrs. ->. roller. shutters.
close.
TWILIGHT CONTROL
The.critical.value.is.pre-set.to.--.
The.twilight.function.is.not.activated.if.the.setting.is.--.
The.brightness.settings.range.from.01.(night).to.15.(early.twilight)..
The.display.shows.the.current.twilight.setting.and.the.new.setting.to.be.made..
The.new.setting.to.be.made.flashes.
TEST Mode
(To.activate.the.test.mode,.a.complete.UP.command.must.be.executed).
The.SC43.can.be.tested.in.this.mode..When.the.test.mode.has.been.activated,.
the.word.TEST.will.appear.on.the.display.
In.the.TEST.mode,.the.sunshade.function.times.are.shortened.