TECHNICAL DATA
MODEL
OUTPUT CHARACTERISTICS
Maximum output current
(1)
Charge absorption voltage
Charge float voltage
Residual ripple
(2)
Charging characteristics
Number of outputs
(3)
INPUT CHARACTERISTICS
Supply voltage
(4)
Frequency
Maximum absorption (230 Vac)
Maximum absorption (115 Vac)
PROTECTION
Reverse polarity
(7)
Overload
Output short circuit
Overheating
AMBIENT CHARACTERISTICS
Operating temperature
Cooling
Humidity
CASE
Material
Colour
Dimensions (WxHxD)
Weight
GENERAL
Connector for remote panel
Safety classification
EMC class
Only DR models
(*)
(1)
Maximum value at normal use or in short circuit.
(2)
At maximum output current on resistive load.
(3)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed
the maximum nominal value of the equipment.
(4)
Without power derating.
(5)
The battery charger measure the input AC voltage and choose the correct working input range.
(6)
With supply voltage specified as and output current equal to the maximum nominal value.
(7)
The protection could be inefficient in some operative conditions.
Cycoloy ® is a registered trade mark of GE Plastics.
QUICK RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
SBC100 ADV
SBC100 ADV DR
8 A
(6)
1,2 A
(6) (*)
2,4 A
Natural
155 x 190 x 75 mm
1,1 Kg
TECHNICAL DATA
SBC140 ADV
SBC140 ADV DR
SBC250 ADV DR
12 A
14,1 Vdc (14,4 Vdc GEL)
13,5 Vdc (13,8 Vdc GEL)
30mV RMS max
Automatic in three stages IUoU
2
260÷207 Vac (260÷207 Vac or 130÷103 Vac
45÷66 Hz
1,8 A
3,6 A
Yes, through fuse
Yes
Yes
Yes
-20 to +70 °C, with power reduction over +50 °C
Forced, with controlled fan
Max. 95% RV without condensation
Aluminium - Cycoloy ®
Anodized - OR5066
1,2 Kg
No
EN 60335-2-29
EN 55022/B
SBC250 ADV
SBC285 ADV
SBC285 ADV DR
25 A
28,2 Vdc (28,8 Vdc GEL)
27,0 Vdc (27,6 Vdc GEL)
*
(5) (
)
)
3,5 A
7,0 A
155 x 242 x 75 mm
2,0 Kg
Yes
GB
12 A
3,0 A
6,0 A
No