Maintenance - Technical Data - Quick SBC NRG+ Série Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MAINTENANCE
The battery charger does not need any maintenance. To ensure optimum performance from the equipment, once a year
check the cables and the electrical connections.
TECHNICAL DATA
MODEL
OUTPUT CHARACTERISTICS
(1)
Maximum output current
Charge ABSORPTION voltage
Charge FLOAT voltage
DC absorption from the batteries
(3)
Residual ripple
Charging characteristics
(4)
Number of outputs
INPUT CHARACTERISTICS
Supply voltage
Frequency
Maximum absorption
(5)
(230/240 Vac)
Maximum absorption (120 Vac)
(5)
Power factor (cos ϕ )
(5)
Efficiency
PROTECTIONS
(7)
Reverse polarity
Overload
Output short circuit
Overvoltage in output
Overheating
AMBIENT CHARACTERISTICS
Operating temperature
Noise level
Cooling
Humidity
CASE
Material
Dimensions (WxHxD)
Weight
GENERAL
Safety standard
EMC Standard
Maximum rated value at normal use or in short circuit.
(1)
With battery charger not supplied by the AC network.
(2)
At 50% of the maximum rated output current on resistive load.
(3)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed the maxi-
(4)
mum nominal value of the equipment.
With supply voltage equal to 230 Vac and output current equal to the maximum nominal value.
(5)
With supply voltage equal to 120 Vac and output current equal to the maximum nominal value.
(6)
Protection may be inefficient in some operative conditions.
(7)
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
®
+
SBC NRG
MINI LOW REV000A
SBC 140 NRG+ FR
SBC 250 NRG+ FR
12 A
(2)
2
0,9 A
(6)
1,7 A
≥ 83%
< 43 dbA @ 1 m
114 x 187 x 71 mm
114 x 252 x 71 mm
1,1 kg

MAINTENANCE - TECHNICAL DATA

SBC 300 NRG+ FR
25 A
30 A
• 14,1 Vdc EL open
• 14,4 Vdc EL sealed / Gel / AGM
• 14,7 Vdc Optima
®
• 13,4 Vdc EL open
• 13,6 Vdc AGM
• 13,8 Vdc EL sealed / Gel / Optima
< 3,5 mA
< 100 mV RMS
Automatic in three stages IUoU
264 ÷ 83 Vac,
with power reduction under 108 Vac
45÷66 Hz
1,8 A
2,2 A
3,4 A
4,2 A
1,00
≥ 84%
≥ 85%
Yes, through fuse
Yes
Yes
Yes
Yes
-15 ÷ +70 °C, with linear power reduction over +45 °C
Variable fan speed
Max. 95% RV without condensation
Aluminium
114 x 252 x 71 mm
1,6 kg
1,6 kg
EN 60335-2-29
EN 55022/B - FCC TITLE 47 PART 15 SUBPART B CLASS B
SBC 500 NRG+ FR
40 A
• 28,2 Vdc EL open
• 28,8 Vdc EL sealed / Gel / AGM
• 29,4 Vdc Optima
• 26,8 Vdc EL open
• 27,2 Vdc AGM
• 27,6 Vdc EL sealed / Gel / Optima
®
3
2,7 A
5,3 A
≥ 87%
< 45 dbA @ 1 m
114 x 275 x 71 mm
1,8 kg
EN
SBC 365 NRG+ FR
15 A
®
®
2,0 A
4,0 A
≥ 86%
114 x 252 x 71 mm
1,6 kg
15

Publicité

Table des Matières
loading

Table des Matières