Fault Finding Guide - SFA Sanicubic 2 Classic Notice D'installation

Masquer les pouces Voir aussi pour Sanicubic 2 Classic:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
UK
9

FAULT FINDING GUIDE

IN ALL CASES, YOU MUST DISCONNECT THE PUMPING STATION
Alarm on Sanicubic® 1 device (IP67)
FAULT DETECTED
flashing red alarm LED
• Water level detection system
faulty
Steady red alarm LED
• Blocked vent pipe
• Blocked discharge
• Blocked pump or out of order
• Discharge too high or excessive
inflow
LED off
• Power outage
• Faulty printed circuit board
Alarm on the Sanicubic® 1 WP/ Sanicubic® 2 Classic/Sanicubic® 2 Pro/ Sanicubic® 2 XL control box
FAULT DETECTED
Siren + flashing red general
• Water level detection system
alarm LED
faulty
Siren + steady red general
• Blocked vent pipe
alarm LED
• The device has encountered the
following problem: blocked pipe,
pump(s) blocked
• The device has encountered a
power failure
Siren + general alarm LED +
• Mains cut
flashing yellow mains LED
10
DISMANTLING
INSTRUCTIONS RESERVED EXCLUSIVELY FOR QUA-
LIFIED PROFESSIONAL SPECIALISTS
If one of the motors cannot be made to operate
correctly, use of that motor can be "disabled" by
setting the corresponding switch on the board
(SW1: switches 1 and 2 for motors 1 and 2).
The motor thus "disabled" can be removed. The
unit operates on the other motor.
FROM THE POWER SUPPLY
POSSIBLE CAUSES
ACTION TO BE TAKEN
• Consult SFA after-sales service
• Check that air flows freely in both
directions in the vent pipe
• Review installation
• Consult the SFA customer services
• Check the electrical system
• Consult the SFA customer services
POSSIBLE CAUSES
ACTION TO BE TAKEN
• Consult the SFA customer services
• Check that air flows freely in both
directions in the vent pipe
• Press the manual start button to reset the
device (alarm off )
• Consult SFA customer services
• To stop the siren, press on the Force Start
button
• Check the electrical system
• Consult the SFA customer services
11
GUARANTEE
2 years guarantee as from its date of purchase
subject to correct installation and correct use.
Only the disposal of toilet paper, faecal
matter, and waste water will be under gua-
rantee. Any damage due to foreign bodies such
as cotton, condoms, sanitary towels, wet wipes,
food, hair, metal, wood or plastic objects, will
not be under guarantee. Solvents, acids and
other chemicals can also cause damage to the
unit, and will invalidate the guarantee.
e
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sanicubic 2 pro

Table des Matières