Installation Manual: Overall assembly diagram
Electrical distribution board
INSTALLATION PRECAUTIONS:
• Temperature at the installation point
should be between 4°C and 35°C
• Position the water heater as close as
possible to the water supply rooms
• If the water heater is installed above a
Phase
Earth
Neutral
Tap in a bathroom
for example
40
16 A circuit breaker,
day/night switch
and 30 mA differential
living area,
install a water retention tank
If your pipes are not made from
copper (PER, multi-layer, etc.), it is
MANDATORY to fi t a copper pipe
with a minimum length of 50 cm
(DTU.60.1) and/or a temperature
limiter at your tank's hot water tank.
Hot water
Dielect.
connect.
CAUTION
(seepage 45)
Cold water
Hot water outlet
Cold water inlet
È
Siphon
Temp. limiter