After clamping, the tool head does not rise or rises too far
from rim
Lamping plate not adjusted.
➥ Adjust the plate.
Column does not tilt
Column tilting cylinder faulty.
➥ Replace column opening cylinder.
No air supply to cylinder.
EN
➥ Hoses folded.
➥ Replace valve.
Clamping arm cylinders leak air
Faulty piston or gaskets.
➥ Replace pistons and gaskets.
The pole tilts violently or too slowly
Release valve incorrect setting.
➥ Adjust the discharge regulators. Hare: speed increase; Turtle: speed reduction.
Tyre pressure gauge needle fails to return to 0
Pressure gauge faulty or damaged.
➥ Replace the pressure gauge.
The lubricator does not work
No oil in lubricator.
➥ Top up lubricator with SAE20 non-detergent oil.
Lubricator broken.
➥ Replace the lubricator.
Wheel lifter not working
Control out of operation.
➥ Check pedal board.
Rises slowly or has insufficient force.
➥ Check for folded hoses.
➥ Adjust delivery on pedal board.
➥ Replace the valve on the lifter pedal control board.
Cylinder leaking air.
➥ Replace cylinder gaskets.
➥ Replace cylinder.
User's manual