Mechanical adjustment of the detection area
Due to local circumstances, it may be necessary to adjust
the detection area of the motion switch. This can be done
by adjusting the motion switch mechanically.
Adjustment of the sensor head/lens system
1
-40° downwards or +90° upwards
+90° sideways or -90° sideways
Segmentation of the detection area
2
In order to hide or segment certain detection areas,
the enclosed plastic parts can be used.
Setting the detection range electronically
Using the „metre" setting screw, the detection area can be
changed electronically within a range of min. 3 m to max.
16 m.