Fault search
Fault
Cause
Light does not
Defective bulb
switch
Back-up turned off
Brightness response set to dark
Power supply interrupted
Detection time not correctly adjusted
Lens is dirty
Light on
Constant movement in the detection area
continuously
(animals, trees, etc.)
ON time is set too long
Independent,
Switching on after a power failure
unwanted
Sunlight on the lens
Switching
Trees, shrubs, etc. in the wind activate
switching
Detection of road transport
Switching inductive loads
(protection, relays, etc.)
Remedy
Replace the bulb
Turn on
Turn setting screw continuously toward bright
Check cable, repair if necessary
Correct area - walk test in the detection area
Clean the lens (damp cloth)
Do not use solvents
Remove the heat source
Readjust the motion switch if necessary
Reduce time using the setting screw
Normal case - Warm-up phase approx. 90 sec.
Change brightness setting
Adjust detection area or partially cover lens with the
enclosed plastic covers
Decrease range (e.g. by setting the set screw to
„Meter") or partially cover lens with the enclosed plastic
covers
Switch noise filter in parallel to the consumer