OUTSIDE AIR INTAKE
The models Petra, Sydney and Dover have the choice to take the primary and secondary entry air from
an adjacent room (or even from outside of the house) or the same room where the stove is installed.
The primary air intake of these models is on the rear side of the stove, so in case that the stove is not
connected with the outside it will be necessary a minimum distance of 6-8 cm to have an enough air
supply to the combustion. In the case you choose the primary air intake from the outside or an adjacent
room it will be enough connecting this entry by a 120 mm diameter driving with the chosen location.
Note that a driving too long or with deviations (elbows), cause a big lost of charge, therefore could cause
some combustion problems. (See drawing D22).
2.1.2.

IRLANDA

This model of stove is provided with axial fans to improve the heat distribution by the ventilation.
The start and the control of the ventilation are made by the three-position switch placed on the right
bottom side (see drawing D23).
These three-positions have the following functions:
-
0 position: the fans are turned off when there is no combustion inside the chamber due to the stove is
provided with a thermostat that controls the fan according to the temperature of the stove.
-
1 position: the fans run in a low speed.
-
2 position: the fans run in a high speed.
FANS CONNECTION:
In the right side of the stove you will find the cable that connects to the electricity network. It is advisable do not
cut it in the entire length because this section is useful when changes in the electrical components are needed.
It is obligated the correct connection of the installation to earth connection.
The installation of the system might be done by skilled labour and qualified under the current rules.
REPLACEMENT OF THE FANS:
The replacement of the electrical components will be done by the
front of the stove. This way you do not have uninstall the stove,
please follow the next steps (see drawing D24).
-
First of all, you will have to screw out the screws in both
sides of the fan protection.
-
When this protection grille has been removed, you will have
a direct access to the fans.
-
The electrical components of the system are placed on the
right side of the stove. To get access to them you will need
to screw out the right fan and remove it.
-
Disconnect and replace the damaged elements and
reattach everything such as before.
2.1.3.

MONZA

The stove Monza has on the top two rings to be used as a plate warmer. These rings
should be handled with the accessory included for this purpose (see drawing D25 and
D26).
The worktop has in both sides two removable handles made in stainless steel.
The model Vitro has another handle in the front of the worktop.
2.1.4.

OXFORD

The rotating cast is made in two parts: the iron grate and the handle in stainless steel. To place the grate
follow the next steps:
D28
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
1.
First of all, we must introduce the rod by the hole on the front of the
stove.
2.
Place the grate with an approximated angle of 45º to introduce the
hook of the rod on the hole of the grate.
3.
Later, place the grate over the firebox (see drawing D27).
The firebox is removable too. To remove it follow the next steps:
1.
Remove the vermiculite pieces (only model Oxford).
2.
Remove the iron grate and the handle.
3.
Finally turn the firebox approximately 45º to get it out by the door of the stove (see drawing D28).