Safety Relais
5. Device overview
5.1 Signal indicator
LED
Power - green
Supply voltage
LED
Actuate - yellow
Sensor actuated
LED
Fault - red
Sensor circuit interrupted
LED
AUX. Relay - yellow
Auxiliary output switched
5.2 Connection terminals
A1 A2
Supply voltage 230 V 50/60 Hz (ELMON rail 41-32)
A1 A2
Supply voltage 115 V 50/60 Hz (ELMON rail 41-82)
B1 B2
Supply voltage 24 V AC/DC
X1 X2
Sensor connection
13 14
Safety-relay switching contact 1
23 24
Safety-relay switching contact 2
31 32
Auxiliary relay switching contact
Z1 Z2
Connection of manual reset
S11 S12
Coding inputs reset
5.3 Versions
Version
Housing
Supply voltage
Auxiliary relay
(switching contact
31 32)
14
ELMON rail
ELMON rail
41-32
41-32 RLU
Housing, 22.5 mm wide, made of polyamide for 35 mm DIN rail mounting
230 V 50/60 Hz
230 V 50/60 Hz
and 24 V AC/DC
and 24 V AC/DC
In the event of
Switches as long
an actuation or
as the sensor is
an error of the
actuated or a
sensor, switches
sensor error is
after 1 sec. for
signalled.
3 sec.
ELMON rail
41-82
acc. to EN 60715.
115 V 50/60 Hz
and 24 V AC/DC
In the event of
an actuation or
an error of the
sensor, switches
after 1 sec. for
3 sec.
ELMON rail
41-82 RLU
115 V 50/60 Hz
and 24 V AC/DC
Switches as long
as the sensor is
actuated or a
sensor error is
signalled.