4.3 Treatment of the cutting set

4.3.1 Sharpening the cutting plate

Note
For sharpening the cutting plate, please contact
Technical Service, see Chapter Technical Service.

4.3.2 Changing the shearing head

Risk of injury caused by sharp
cutting plates!
Handle the shearing head of
Clipper FAV5 with appropriate
WARNING
caution.
2
Fig. 4
Press ON/OFF switch 3 to switch off Clipper FAV5,
see Fig. 4.
Press shearing head lock 2, see Fig. 4.
6
3
Fig. 5
Press forward shearing head 12, see Fig. 5.
Detach shearing head 12.
Clean open hinge 1 with a brush.
Install shearing head 12 on hinge 1.
Plug in the power cord of Clipper FAV5.
Press ON/OFF switch 3.
Slightly push shearing head 12 towards Clipper
FAV5.
Shearing head 12 will click into position.
3
Check that shearing head 12 is correctly seated on
Clipper FAV5.

4.3.3 Lubricating the shearing head

Clean the upper and lower cutting plates with a
soft cloth or brush. Make certain that the gaps
between the cutting teeth are cleaned properly.
Slightly lubricate the upper and lower cutting plates
with special lubricant for shearing heads GT604.