EUROM Outdoor Heatpanel Mode D'emploi page 12

Masquer les pouces Voir aussi pour Outdoor Heatpanel:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Permanent installation: The Outdoor Heatpanel is designed to be installed at a
permanent location and be connected directly to the mains. The installation must be
equipped with an on/off switch. For safety reasons, this installation must be carried out
by a professional electrician.
Temporary facility: As a temporary facility, the Outdoor Heatpanel can be directly
connected to a socket via its electric cable and plug. The Outdoor Heatpanel is then
switched on and off by inserting or removing the plug from the socket. Ensure that the
electric cable does not hang off sharp edges, is not twisted around sharp corners, cannot
be dragged along and does not come into contact with any hot surfaces.
Important: electrical cable and plug form one, single unit. If the electric cable or plug
becomes damaged, they must be replaced in their entirety by an electrician. Only allow
original parts to be used!
Location
The Outdoor Heatpanel must be installed with its lowest point at least 180 cm from the
ground for both wall and ceiling installation.
When installing Outdoors, under a roof covering, the most effective installation height is
between 220/240 and 270 cm. Never hang the Outdoor Heatpanel higher than 320 cm
above the ground. Minimum distance to ceiling or sidewall: 20 cm., zie also picture. Keep
on at least one meter around the Heatpanel free of obstacles.
Ceiling installation:
Carefully select the right position for your Outdoor Heatpanel, taking the regulations into
account. The device must be installed on a non-flammable surface. The surface must also
be free from vibrations, completely vertical (when mounting on a wall) and sufficiently
sturdy to bear the device correctly for the long-term.
Attention:
 Make sure that the Outdoor Heatpanel can never radiate heat towards the ceiling!
 The Outdoor Heatpanel must not be installed right in front of, over or under an
electrical socket.
 Never place the unit above or within one metre of a tap or other source of water. Do
not install the unit in a damp environment, such as a bathroom, washing area or
similar.
12
Wall installation:

Publicité

Table des Matières
loading

Table des Matières