deactivation are calculated automatically.
The pump output, if it is enabled, will activate the relay marked as "chlorinator" when the pump is activated and
deactivated. This contact can be used to enable operation of a salt chlorinator or to remotely control the pump status.
10 - VERSION DE SOFTWARE
An informative screen showing the software version of the time controller.
11 - FACTORY RESET
El último submenú de los ajustes permite el reseteo total de la configuración del controlador. A través de una pregunta
The last submenu in configurations enables a total reset of the configuration of the controller. Through a question, the
user can recover the factory configuration and start the start-up wizard.
The factory reset eliminate all settings made except for the alert history and the total operating hour counter on the
pump.
Note 1: The
button is disabled if the configuration menu is active.
Note 2: If no selection is made in the configuration menu, the stand-by screen will return after 15 seconds.
Note 3: The values changed in the start-up wizard as well as in the configuration menu will be stored in case of
power cut, therefore reconfiguration is not required.

12.10. WARNING MANAGEMENT

During normal operation of the time controller there may be alerts which are mostly merely informative, and only in
some cases may also stop the pump.
There are luminous and acoustic type alerts. The luminous only alerts may be considered a warning, but in no case
involve modification to the normal operation of the controller. These alerts may occur due to:
-Dirty pump basket alert
-Dirty sand filter alert
These alerts can be reset manually.
There are other types of alerts that may be considered alarms, and the luminous alert will be accompanied by an
acoustic alert. The acoustic alert is not continuous, and the amount of time it sounds will depend on the time the alert
is active. These alarms are:
-Excess ammeter consumption of the motor
-Detection of the pump is operating without water (if the configurations are activated)
These two alarms are self-resettable, up to a point which very infrequently occurs in which the pump is totally blocked,
until an authorised operator with manually reset is the fault with the
generate an entry in the alert history.
Remember that only the alarm about ammeter consumption on the motor is always active and cannot be deactivated.
All the other alerts/alarms are deactivated by default and are only operative for supervision by manually activating
them.
button. The alerts considered alarms
F2
26