OPERATION

REMOTE CONTROL

With the key „Remote" the remote control of FL 1000 HP can
be switched off.
Switching off the remote control may be necessary to avoid
that several units FL 1000 HP on one construction site disturb
each other.
The remote control can only be switched off on the keypad of
the instrument.
ON/OFF
Switch on the unit with key
. The key is blinking and the automatic self-levelling procedure is
working. During this process all keys are inactive until the self-levelling process is completed.
ROTATION
After completion of the self-levelling procedure the unit rotates with maximum speed (500 rpm). After
30 sec. the TILT-function automatically turns on (see p. 16). Press key
shortly to change the speed
from 500 rpm to 200 rpm. Press the key
long to switch off the rotating laser.
SCANNING
Press the key
to switch from rotation to scanning mode. With this key the scan range can be
changed in three steps: 60°, 30° and 10° as well as to the laser point mode.
With the keys
and
the scan direction can be changed counter-clockwise / clockwise.
15