Optimate TM290 Mode D'emploi page 6

Masquer les pouces Voir aussi pour TM290:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
CHARGE PROGRAM
1
2
Low Volt
TEST before
Temperature
Start (0.5V)
charge
Protection
BMS reset
STEP 1
Low Volt Start
≥ 0.5V
STEP 2
TEST LEDs
6 : GREEN
TEST before
7 : YELLOW
charge
8 : RED
STEP 3
Temperature
check
STEP 4
LED #3 : RED
ULTRA LOW
VOLT SAVE
STEP 5
LOW VOLT SAVE
STEP 6
TEST - cell
damage
6
3
4
LOW VOLT
Ultra LOW
SAVE /
check
VOLT SAVE
cellmonitoring
Charger will not proceed without user interaction.
LED #2 REVERSE POLARITY:
1
are incorrect. The charger is electronically protected so no damage will
2
result, and the output will remain disabled until the connections are
corrected.
BMS RESET:
protects against deep discharge. Disconnect the charger from mains supply.
Wait for LED #1a/1b to go out. Reconnect to mains supply. A special BMS
reset pulse is delivered for up to 5 seconds. The program should continue to
STEP 4.
Battery voltage check - OptiMate Lithium automatically activates
if connected battery voltage is at least 0.5 Volt.
V
TEST LEDs #6/7/8 indicate the battery condition prior to charging. Consult the
table on page 2 to match TEST LED indication to an estimated state of
charge percentage (SOC%).
During the test:
OPTIMIZE minimum charge time is set according to the test result, varying
between 10 minutes for a battery with 80% or higher state of charge to 120
6
minutes
7
for a battery with 40% or less state of charge.
8
Ambient temperature is measured to determine charge voltage parameters.
TEST
LOW TEMPERATURE WARNING - LED #8 (red) flashing: The temperature
measured at OptiMate Lithium is below -20 degrees Celcius or 4 degrees
Fahernheit, below the safe charging AND discharging zone for LiFePO 4
batteries.
Charging commences after 10 seconds.
%
V
IMPORTANT: If this mode engages read the section
NEGLECTED BATTERIES
This mode engages if the battery was more than 90% discharged / voltage
3
is below 12.8V safeTº: Charge current is automatically adjusted according
to voltage and ambient temperature measured during the test.
VERY LOW VOLTAGE SAVE for batteries between 0.6V and 8.8V :
Current starts at 125mA and will increase to 325mA depending on charge
progress. If the voltage did not rise above 8.8V within 2 hours, charging will
be suspended and the TEST LED #8 (red) will flash, indicating the battery
may have suffered permanent damage or a professional assessment is
required.
LOW VOLTAGE SAVE for batteries between 8.9V and 12.8V (16V):
Maximum current is set to 1.25A. The battery's charge acceptance is
monitored for unusual behaviour.
A healthy LiFePO
otherwise charging will be suspended and TEST LED #8 (red) will flash,
indicating the battery may have suffered permanent damage or a
professional assessment is required.
5
6
7
TEST -
Cell-balancing
cell damage
CHARGE
for batteries with a battery management system (BMS) that
0
10
30
7
8
8
0.5V
12.80V
13.00V
on the preceding page.
battery will progress to CHARGE mode within 4 hours,
4
8
9
TEST after
OPTIMIZE
CHARGE
Lights when the battery connections
60
90
6
6
7
7
13.13V
13.3V
13.6V+
VERY FLAT
10
OptiMate
maintenance
100%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tm290euTm291Tm291usTm294Tm294ukTm298 ... Afficher tout

Table des Matières