Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first time. Adhere to
the safety information for the correct and safe use of the unit.
Intended use
Only use the AquaOxy series, in the following text termed unit, for pumping air oxygen having an air temperature of
between –15°C and +45°C to aerate garden ponds.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low voltage directive
(73/23/EEC). The following harmonised standards apply: EN 60335-1, EN 60335-2-55, EN 55014-1,
EN 55014-2, EN 61000-3-2, EN 61000-3-3.
Safety information
OASE has manufactured this unit according to the highest quality standards and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accordance
with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons, who cannot recognise
possible danger or who are not familiar with these operating instructions, are not permitted to use the unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions when passing the unit
on to a new owner. Ensure that all work with this unit is only carried out in accordance with these instructions.
The combination of water and electricity can lead to danger for life and limb, if the unit is incorrectly connected and
misused.
Never operate the unit when submersed or standing in water; only use the supplied transformer for its operation. Ensure
that the transformer is placed at a minimum 2 m distance from the pond edge at a dry and flood protected place. Never
open the unit housing or its attendant components, unless this is explicitly mentioned in the operating instructions.
Compare the electrical values of the power supply with those on the type plate on the packing or on the unit itself. For
your own safety, consult a qualified electrician when you have questions or encounter problems! Protect the connection
cable when burying to avoid damage. Only use cables approved for outside use. Protect the plug connection from
moisture.
Start-up
Prior to this observe the following operating steps: Connect the air hose to the unit prior to switching on. We recommend
to fit the aeration stones approx. 30 cm below the water surface. Keep the length of the air hoses as short as possible.
Protect the connection cable when burying and connect the transformer to a socket. After a short period air escapes from
the stones.
Electrical connection
Only entrust an authorised expert to carry out the electrical connection in accordance with the German EVU and VDE.
The VDE 0100, part 702, are valid for all installations. Deviations from the rated voltage +6% and -10%. Please refer to
the type plate for all capacity and performance data. Carry out all work on the unit when isolated.
Cleaning
Disconnect the power supply first, then secure the unit to prevent unintentional switching on. Should the performance
reduce, clean the air intake opening in the base of the housing.
Wearing parts
Diaphragms are wear parts and are excluded from the warranty.
6
Ursache
- Netzspannung fehlt
- Transformator defekt
- Membranen defekt
- Regulierventil falsch eingestellt
- Ventile verschmutz
- Membrane defekt
- zu hohe Verluste in den Zuleitungen
- Regulierventil falsch eingestellt
Abhilfe
- Netzspannung prüfen
- Transformator ersetzen
- Membranen (6) austauschen, Lüftungschlitze (1)
reinigen
- Einstellung prüfen
- Reinigen
- Membrane (6) austauschen
- Schlauchlänge (4 u.5) auf min. reduzieren
- Einstellung prüfen