Données Techniques; Caractéristiques Sonores - CTC EcoAir 510M Manuel D'installation Et De Maintenance

Table des Matières

Publicité

3. Données techniques
Electrical data
Input power
1)
1)
Output power
COP
1)
2)
Rated current
Max start current
Water volume
Refrigerant quantity (R410A, fluorinated
greenhouse gases GWP 2088)
CO2 equivalent
High pressure switch
Max. operating pressure water (PS)
Dimensions (D x W x H)
Compressor / Oil type
Air flow 100%
Fan speed
Fan, max power
Weight with/without packaging
3)
Sound power
IP-cl.
Heat pump Keymark Cert. No.
At 35°C water temperature. +7 @ 20 rps / -7 °C @ 90 rps. According to EN 14511.
1)
At 120 rps (from factory max 90 rps). Incl. Grundfos UPM GEO 25-85 charge pump.
2)
Sound power level in accordance with EN12102/ISO3741 at test conditions A7 W47/55 and A7
3)
W30/35.
No annual leakage control of the refrigerant is required.
!
Remarque : en cas d'écart, ce sont les données de la
plaque signalétique de l'appareil qui s'appliquent. Pour les
interventions de maintenance, contrôlez toujours les données
de la plaque signalétique du produit pour connaître la quantité
de réfrigérant correcte.
Caractéristiques sonores
CTC EcoAir 510M
* Le bruit spécifié doit être considéré comme une indication dans la mesure
où le niveau est affecté par la vitesse du compresseur et du ventilateur,
ainsi que par l'environnement. La valeur supérieure correspond à une
réflexion à 100 % par le sol et les murs (béton lisse). Valeurs conformément
à EN12102 à A7/W35.
10
CTC EcoAir 510M 230V 1N~
CTC EcoAir 510M
kW
kW
A
A
liter
kg
ton
bar
bar
mm
545 x 1245 x 1080
Twin rotary / PVE FV50S
m3/h
rpm
W
kg
dB(A)
Sound power
Sound pressure 5 m *
59.7 dB(A)
230V 1N~ 50Hz
0.54 / 2.42
2.52 / 6.60
4.67 / 2.73
20.8
2.8 A
1.9
2.2
4.594
45
2.5
3800
Modulating
73
148/119
59.7/55.6
IPX4
012-061
Sound pressure 10 m *
37-40 dB(A)
30-33 dB(A)