Operation | Installation |Service manual
Manuale di utilizzo | Installazione | Manutenzione
X-light | Privilege | Evolution | Breeze | E-Breeze | Silence Plus 2G | Elegance 2G
3.4 Inlet pump
Install the inlet pump in a dry, ventilated place. The pump can't be submerged or exposed to sprays.
Install a fuse in the power supply circuit.
The pump can be assembled horizontally as well as vertically (in this case, the pumping unit must
face downwards).
Install the filter before the pump.
Install a vent valve to prevent siphoning phenomena, especially if the toilet is installed below the
floating line
WARNING: The inlet pump must not be used as a check valve. Failure to use a vent valve
may result in flooding, loss of the property, injuries, or even death.
3.5 CUT-OUT control panels
Apart from the control panel "All in One" which integrates the controller in the wall interface, all
panels are equipped with a control unit that can be installed either directly in the toilet or in a recess
outside if more convenient. All control panels are fitted with specific electric connectors.
3.5.1 Cut out for All-in-one control panel:
3.5.2 Cut out for Multiframe control panel:
Thetfordmarine.com
TECMA S.r.l. | Via Flaminia | Loc Castel delle Formiche | 05030 Otricoli (TR) | Italy
MACERATOR TOILETS
TOILET MACERATRICI
57
Rev. 1 | 2018