SW24.D
Remote control management
Remote control button programming on 1st
channel (step-by-step or open, see P18)
Waiting the code (press the remote control
button), the receiver is empty
Waiting the code (press the remote control
button), the receiver is set as rolling code
1CH
Waiting the code (press the remote control
button), the receiver is set as fixed code
Remote control button programmed on 1st
channel as 1st code in the memory
Remote control button programmed on 1st
channel as 55th code in the memory
Memorizzazione di un tasto sul 2° canale
(pedonale o uscita 12, vedere P20)
Waiting the code (press the remote control
button), the receiver is empty
Waiting the code (press the remote control
button), the receiver is set as rolling code
2CH
Waiting the code (press the remote control
button), the receiver is set as fixed code
Remote control button programmed on 2nd
channel as 1st code in the memory
Remote control button programmed on 2nd
channel as 55th code in the memory
Remote control button memory position
check
Waiting the code (press the remote control
button), the receiver is empty
Waiting the code (press the remote control
button), the receiver is set as rolling code
CTRL
Waiting the code (press the remote control
button), the receiver is set as fixed code
Remote control button in position n.1 in the
memory on 1st channel
Remote control button in position n.99 in the
memory on 2nd channel
Button not in the memory
Remote control deletion
Use ▲▼ buttons to select the n. of the remote
control code to be deleted.
Code stored in position 3 in the memory as
1st channel.
Press OK to delete
ERAS
Code stored in position 3 in the memory as
2nd channel.
Press OK to delete
Memory position n. 3 free
Deletion of all remote controls code from the
memory of the receiver. Press OK and hold
for 5 s to confirm
Setting the operating mode of the receiver of the control board:
The receiver of the control board operates in Rolling code mode or
Fixed code according to the first programmed remote control button:
- if the first programmed remote control button is Rolling Code, the
receiver only accepts Rolling Code remote controls
- if the first programmed remote control button is Fixed Code, the re-
ceiver only accepts Fixed Code remote controls
To change the receiver operating mode it is necessary to delete all
the remote controls in the memory (ERAS-ALL) and program the first
remote control according to the desired type.
Factory reset
Display
Button
Description
Msg
Waiting to press OK for 5 s to load factory set-
OK
oooo
tings.
Note:
Factory reset does not require performing a new gate travel calibra-
tion as it does not reset parameters P09-10-11-12-13-14-15-16-17-
18-19-20-21-22-25-26-31-36-43.
10
Msg
Counters
display ex.
Display
Button
Msg
-
A025
oooo
▼
4075
In the example above, the gate has performed:
rc
025 x (10000) + 4075 = 254075 total cycles
fc
▼
P019
▼
1234
1001
In the example above, the gate has performed:
019 x (10000) + 1234 = 191234 partial cycles
1055
OK
oooo
Alarms history
oooo
Display
Button
Msg
rc
fc
▲▼
X.FYY
2001
2055
-
1.F03
-
2. no
OK
oooo
none
Protection level of the control board (default = OFF)
OFF
No protection
rc
1
Protection of menus PAR, DEF, LRNE e LRN
fc
2
Protection of menu RAD
3
Full protection of the control board
1001
DIP-switch functions
2099
Dip
Function
no
Motor with/without
Dip 2
encoder
-
LED functions
1003
LED
Status Description
OFF
2003
DL1
ON
3
OFF
41
ALL
ON
OFF
45
ON
OFF
51
ON
OFF
52
ON
OFF
61
ON
OFF
62
ON
OFF
63
ON
EN
Description
First number of absolute cycles (multiplied by
10000)
Second number of absolute cycles
First number of partial cycles (multiplied by
10000)
Second number of partial cycles
By pressing OK for more than 5 s the control
board resets the count of the number of partial
cycles
Description
Use ▲ ▼ keys to scroll the alarms of the control
board in chronological order (last 9 memorized
alarms, 1 most recent alarm, 9 oldest alarm).
X indicates the position of the alarm, YY the type
of alarm (see the alarm list table)
In position 1 alarm 03 is present (see the alarm
list table)
In position 2 there is no alarm
Press OK until the display shows "oooo" to clear
the list of memorized alarms
Status Description
The motors are equipped with
OFF
encoders
The motors are not equipped with
ON
encoders
Power supply not present
Power supply present
When the motor M1 is running: encoder signal absent
(encoder not working)
When the motor M1 is running: encoder signal present
(it appears as a very rapid flashing according to the ro-
tation speed of the motor)
When the motor M2 is running: encoder signal absent
(encoder not working)
When the motor M2 is running: encoder signal present
(it appears as a very rapid flashing according to the ro-
tation speed of the motor)
Step-by-step input (terminal 51) not engaged
Step-by-step input (terminal 51) engaged
Pedestrian input (terminal 52) not engaged
Pedestrian input (terminal 52) engaged
Stop contact (terminal 61) open (engaged)
Stop contact (terminal 61) closed (not engaged)
Photocell on closing engaged (terminal 62 open)
Photocell on closing not engaged (terminal 62 closed)
Photocell or safety edge engaged (terminal 63 open)
Photocell or safety edge not engaged (terminal 63
closed)