will switch of the generator. If that occurs, disconnect all the connected appliances
and try to discover the cause and to repair it before re-using the generator. If
overload is the cause, then reduce the load.
CAUTION! If the AC-protection or the circuit breaker goes into operation regularly,
this could damage the generator or the appliances connected to it.
The circuit breaker for the generator comes in two versions:
1. As a press knob; to reset, press
the knob once again.
2. As a switch; to reset, press the ON
side again.
Attaching the wheel set (mm5500 and mm6500)
NUT, FLANGE M8
BEFORE PUTTING INTO OPERATION
BRACKET
RUBBER FOOT
NUT, FLANGE M8x25
Check the oil level
WARNING!
For general use at all temperatures, the
recommendation is to use SAE 10W-30 or 10W-40 oil.
Check the oil level by using the oil dipstick each time
before you start the generator. Always gauge when the
generator is switched off and has cooled down! Top up
the oil level up to the maximum level of the dipstick or
until the oil starts running out of the opening. Finally,
tighten the oil dipstick in the opening.
Try not to start the motor without filling the sump with the correct
quantity of the correct oil. Your generator arrives from the factory
without oil in the sump; if you use it without oil, you will damage
the motor.
NUT, FLANGE M8
NUT, FLANGE M8x16
28
WHEEL 10"
SEALER ø27xØ16.5
OIL DIPSTICK
(not closed)
Normal
oil level
Lowest oil level
AXLE