EUROM MM3500 Manuel D'instructions page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description
1.
Tank cap
2.
Fuel tank
3.
Fuel gauge
4.
Choke
5.
Fuel cock
6.
Air filter
7.
Recoil starter
8.
Oil dipstick
9.
Motor switch
10. Sockets
11. Circuit breaker
12. Display
13. Earth-wire connection
14. Oil drain plug
15. Exhaust
16. Spark arrestor
17. Spark plug
Fuel gauge (3)
Earth-wire connection (13)
Your generator needs to be earthed properly in order to prevent electric shocks. For
that purpose, your generator is equipped with an earth-wire connection.
You create a correct earth-wire by inserting a sturdy copper wire (minimally 12
AWG) between the earth-wire connection of the generator and a copper tube or pin
that is driven into the ground. Contact your local electrician to make sure that you
have complied with all the local regulations.
Circuit breaker (11)
Your generator is protected by an AC-protection or a circuit breaker. If the
generator is overloaded or a short circuit occurs, the AC-protection/circuit breaker
FULL
27
Inspection window
EMPTY