Functional Description; Technical Data; Delivery Check - LK Armatur SmartComfort CT LK 100 Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
GB
ENGLISH

Functional Description

LK 100 SmartComfort CT is an electronic constant temperature con-
troller for water supplied heat in radiators and underfl oor heating
systems. It can also be used for solid fuel boilers connected to an ac-
cumulator tank. The SmartComfort adjusts the mixing valve so that
the heating always has the supply temperature that has been set.

Technical Data

Primary voltage, adapter
Secondary voltage, adapter 24 VDC
Connector, AC adapter
Power consumption
Ambient temp.
Control range
Angle of rotation
Torque
Manual operation
Air humidity
Enclosure class, actuator
Enclosure class, AC adapter IP 20
Protection class
Warning!
Risk of personal injury!
Before starting installation work disconnect power supply.
Make sure to adhere to valid safety regulations.
Installation
Installing the Actuator:
1.
Turn the axle of the mixing valve A counterclockwise and re-
move the knob without changing the position of the axle.
2.
Screw the fi xation bolt B in a suitable hole on the mixing valve A.
Remove possible existing bolt. Push the adapter C on the mixing
valve axle so that the axle bottoms in the hole. The supplied
adapter C suits most valve axles. Other versions of this adapter
are available as accessories. Please contact LK Armatur AB for
more information.
3.
Fit the actuator D to the adapter C. The bolt B should fi t in the
intended hole on the actuator.
4.
Fit the knob E so that the indicator points to the counterclockwise
end position. Tighten the knob with the washer and the screw F.
5.
Use a screwdriver to turn the decoupling screw G to the posi-
tion with hand symbol
E from one end position to the other. It is important that the
motor can be turned the whole turning angle (90°).
6.
Connect the AC adapter to the connector marked
the actuator. Important! The AC adapter must never be ex-
posed to water.
7.
Connect the cable from the supply sensor to the connector
marked
on the actuator.
8.
Use a screwdriver to turn the decoupling screw G back to the
Automatic position
A
B
C
100-240 VAC, 50/60 Hz
Europlug CEE 7-6 or
USA: NEMA 1-15 or UK: BS 1363
< 3 VA
Min. 0°C/Max. +50°C (in operation)
Min.32°F/Max. 122°F (in operation)
5°C - 99°C, 41°F - 210°F
90° /clockwise and counterclockwise
5 Nm
Yes, when needed
<90% Rh, without condensation
IP 40 (according to EN 60529)
III SELV (EN 60730-1) (double insulated)
. Turn the valve with the knob
.
D G
E
Installation, use and maintenance must be carried out by tech-
nical qualifi ed personnel. All instruction in this manual should
be observed and understood before starting any work with the
SmartComfort. For safety reasons no modifi cations or amend-
ments are allowed. Only original AC adapter is allowed.

Delivery Check

Check that the delivery includes the following components:
Actuator
Mounting kit (Fixation bolt, fi xing screw, lockwasher,
adapter)
Knob with indicator
Flow line sensor with 1 m cable
AC adapter 100-240 VAC, 50/60 Hz with 1.8 m cable
Cable ties
Warning!
Avoid touching the hot supply line pipe when clamping
the supply sensor.
Installation of the Supply Sensor
Use the supplied cable ties to clamp the supply sensor on an uninsu-
lated part of the supply line aproximately 1 m after the mixing valve.
If necessary, thermal conductivity paste can be applied. The pipe then
must be insulated to obtain the best temperature measurement.
Connect the sensor cable to the notch marked
LK 100 in an Underfloor Heating System
LK 100 in a Solid Fuel System
on
F
Risk of burns!
on the actuator.
3

Publicité

Table des Matières
loading