2. Description
The device comprises:
a – liquid container (16l)
b – safety ventilator
c – pump with pump handle
d – hose (2.5m)
e – spraying tube
f – handle with fixing system
g – nozzle
h – two transport wheels
i – push-handle with storage space
j – filling funnel
k – Various washers and rubbers
The materials used for the device are resistant to acid,
alkaline and corrosion. The device seals hermetically
and is very durable.
The spraying tube must be screwed onto the handle
before use.
3. How it works
Remove all the packaging material and check that
all the parts are present. Screw the lance on to the
spray gun. Select a nozzle and screw it on to the
front of the lance.
Filling:
 Open the tank by firmly unscrewing the filler cap
(including the pump) anticlockwise off the tank
(with the spray gun in the locked position).
Note: the funnel can be found in the cap, it must
stay in place! Now fill the tank with the required
liquid (following manufacturer's instructions!) and screw the filling cap with pump back into
place. When the pump is replaced, the liquid must remain under the safety level. If there is
too much liquid the pump will be unable to build up pressure.
Pressurising:
 Unlock the pump by turning the handle 45° in an anti-clockwise direction.
 Now pressurise the liquid by pulling the pump handle upwards as far as it will go and then
pushing back down. Repeat this about 25 times in order to obtain sufficient pressures. Lock
the pump by rotating the handle 45° clockwise. The device is now ready for use. If too much
pressure has been built up, the air will escape via the safety ventilator.
Spraying:
 Spraying will begin when you depress the lever on
the handle and liquid will be released via the
nozzle.
 The spray gun can be locked by sliding the red
slide on the spray gun backwards so that you can
spray continuously.