0
The reset procedure involves complete restoration of the default values, parameters and memory settings set in the factory.
All memory locations will be reset and hence all your personal welding settings will be lost!
Set the welding power source ON/OFF switch to "O" to switch the unit off.
Hold down both buttons simultaneously.
S3
S5
Set the welding power source ON/OFF switch to "I" to switch on the unit.
RECALL PARTIAL SETUP ?
E1
Select the following setting with the encoder:
RECALL FACTORY SETUP ?
Exit without confirmation
Press any button (except S2).
This action will automatically close the menu.
Exit with confirmation
S3
Press the button.
MEMORY RESETTING NOW........ The message appears on the following displays: D2
This action will automatically close the menu.
Wait for the memory clear procedure to terminate.
8
SET-UP (INITIAL SET-UP OF THE WELDING POWER SOURCE)
Set the welding power source ON/OFF switch to "O" to switch the unit off.
S3
Hold down the button.
Set the welding power source ON/OFF switch to "I" to switch on the unit.
SET UP The message appears for a few seconds on the following displays: D2
SELECT LANGUAGE:
S3
Use this button to scroll the settings to edit.
E1
Using the encoder, edit the value of the selected setting.
Press any key (except S3) to save the setting and quit the menu.
*1: The value of this parameter can be set as a percentage of the welding current or as an absolute value expressed in Amperes.
*2: This setting enables slow pulsed mode.
*3: This setting enables fast pulsed mode.
Cooler activation
34
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
The message appears on the following displays: D2
The message appears on the following displays: D2
Tab. 1 - Setup settings
SETTING
MIN
SELECT LANGUAGE:
COOLER ACTIVATION
OFF
START CURRENT
%
FINAL CURRENT
%
CURRENT HF
20 A
HF TIME
0.5 s
KIND OF PULSE
SLOW (*2)
PILOT ARC
OFF
SIMULTANEOUS ACTIONS
DEFAULT
MAX
ITALIANO
ENGLISH
FRANÇAIS
DEUTSCH
ESPAÑOL
DUTCH
PORTUGUES
SUOMI
CESKY
POLSKI
DANSK
AUT
ON
A
A
*1
A
A
*1
SYN
220 A
2.0 s
3.0 s
SLOW
FAST (*3)
OFF
ON
SIMULTANEOUS ACTIONS
E E E E
GB
GB
GB
GB