Page 1
ATLANTIC MANUAL TÉCNICO DE INSTRUCCIONES. EQUIPOS INVERTER DE SOLDADURA AL ARCO. GB TECHNICAL INSTRUCTIONS MANUAL. ARC WELDING INVERTER EQUIPMENT MANUEL TECHNIQUE D'INSTRUCTIONS. ÉQUIPEMENTS INVERTER DE SOUDAGE À L’ARC. ATLANTIC 180 Ref. 22290180AC ATLANTIC 200 Ref. 22290202AC ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES.
ATLANTIC 180/200 2/30 E ÍNDICE DE TEMAS. 1. SEGURIDAD………………………………………………………… Pág 3 2. INFORMACIÓN GENERAL DEL PRODUCTO…………………… Pág 4 3. INFORMACIÓN GENERAL DE LAS FUNCIONES………………. Pág 5 4. CARACTERÍSTICAS DE LAS PRESTACIONES……………………. Pág 5 5. ESPECIFICACIONES TÉCNICAS…………………………………. Pág 5 6. DESCRIPCIÓN Y CONTROL DE FUNCIONAMIENTO…………...
ATLANTIC 180/200 3/30 1. SEGURIDAD. La soldadura puede provocarle lesiones a usted y a los demás, por lo que le rogamos que implemente los medios apropiados de protección durante la soldadura. Para más información consulte la Guía de Protección de Seguridad para Operarios, la cual cumple los requisitos para productos manufacturados en materia de prevención de accidentes.
rogamos que se ponga en contacto con el distribuidor o el centro de asistencia de GALA GAR para conseguir el soporte técnico necesario. 2. INFORMACIÓN GENERAL DEL PRODUCTO El diseño exclusivo de la canalización de aire y de la estructura eléctrica de esta serie de máquinas puede acelerar la disipación del calor de la fuente de potencia así...
ATLANTIC 180/200 5/30 3. INFORMACIÓN GENERAL DE LAS FUNCIONES Descripción de las funciones: Función de cebado Hot start: facilita y hace más fiable el cebado del arco en la soldadura MMA. Función VRD: mantiene la seguridad del operario cuando la máquina está parada.
ATLANTIC 180/200 6/30 6. DESCRIPCIÓN Y CONTROL DE FUNCIONAMIENTO LED de sobrecalentamiento: Indica sobrecalentamiento en el equipo. El LED encendido nos señala que la temperatura interior de la máquina es demasiado alta y que ésta se encuentra modo protección contra sobrecalentamientos.
Page 7
ATLANTIC 180/200 7/30 1) Esta máquina se suministra con un cable primario de alimentación de corriente. Conectar el cable de alimentación de corriente a la potencia nominal de entrada. 2) Para evitar la oxidación, debe conectarse con fuerza el cable primario a la toma correcta.
ATLANTIC 180/200 8/30 8. RECOMENDACIONES DE USO Y SEGURIDAD Entorno de soldadura 1) La soldadura debe llevarse a cabo en un entorno seco con un nivel de humedad del 90% o inferior. 2) La temperatura del entorno de trabajo debe situarse entre -10º C y 40ºC.
ATLANTIC 180/200 9/30 9. MANTENIMIENTO. La operación siguiente requiere un conocimiento profesional suficiente en el tema eléctrico y un completo conocimiento en materia de seguridad. Los operarios deben estar en posesión de los correspondientes certificados de cualificación que demuestren sus habilidades y conocimientos.
ATLANTIC 180/200 10/30 10. LOCALIZACIÓN DE AVERÍAS La operación siguiente requiere un conocimiento profesional suficiente en el tema eléctrico y un completo conocimiento en materia de seguridad. Los operarios deben estar en posesión de los correspondientes certificados de cualificación que demuestren sus habilidades y conocimientos.
Page 11
ATLANTIC 180/200 11/30 LISTA DE PIEZAS PRINCIPALES PARA REPARACION Y MANTENIMIENTO. Nº. Código del material Nombre del material 10007251 IGBT-FGH40N60 10007253 IGBT-FGH60N60 10037794 IGBT-GD60SGK60T2S 10006272 Tubo rectificador de corriente WSAD92-02 10006248 Tubo rectificador de corriente D92-02 10006271 Tubo rectificador de corriente FFA60UP30DE 10005801 Condensador electrolítico CD-470uF-400V...
ATLANTIC 180/200 12/30 1. SAFETY Welding may result in injury to you and others, so please implement protection during welding. See more details in Safety Protection Guidebook for Operator which meets the requirements to manufactures on accident prevention. Operate this equipment by trained professional only! Use welding labor protection supplies with approval of safety ...
If you still cannot understand fully, or you still cannot solve the problem, please contact the dealer or the service center of GALA GAR to obtain professional support. 2. PRODUCT OVERVIEW Unique electric structure and air channel design in this series of machines can speed up the heat rejection of the power device as well as improving the duty cycles of the machines.
ATLANTIC 180/200 14/30 3. FUNCTION OVERVIEW Various function designs Hot start arc ignition function: make the arc ignition in MMA welding easier and more reliable. VRD function: keep the operator safe when the machine is idle. Anti-sticking function: reduce working strength in welding.
ATLANTIC 180/200 15/30 6. OPERATION CONTROL AND DESCRIPTION 1. Overheating LED: indicate overheating. Overheating LED on indicates that the temperature inside the machine is too high and the machine is under overheating protection status. 2. Power LED: To indicate the power. Power LED on indicates that the power switch of the machine is on.
Page 16
ATLANTIC 180/200 16/30 1) A primary power supply cable is available for this welding machine. Connect the power supply cable to the rated input power. 2) The primary cable should be tightly connected to the correct socket to avoid oxidization.
ATLANTIC 180/200 17/30 8. CAUTION Working Environment 1) Welding should be carried out in dry environment with humidity of 90% or less. 2) The temperature of the working environment should be between -10℃ and 40℃ . 3) Avoid welding in the open air unless sheltered from sunlight and rain. Keep it dry at all times and do not place it on wet ground or in puddles.
ATLANTIC 180/200 18/30 10. TROUBLESHOOTING. The following operation requires sufficient professional knowledge on electric aspect and comprehensive safety knowledge. Operators should be holders of valid qualification certificates which can prove their skills and knowledge. Make sure the input cable of the machine is disconnected from the electricity utility before uncovering...
Page 19
ATLANTIC 180/200 19/30 SPARE PARTS LIST FOR MAINTENANCE Material Code Name of Material 10007251 IGBT-FGH40N60 10007253 IGBT-FGH60N60 10037794 IGBT- GD60SGK60T2S 10006272 Rectifying tube WSAD92-02 10006248 Rectifying tube D92-02 10006271 Rectifying tube FFA60UP30DE 10005801 Electrolytic capacitor CD-470uF-400V 10037138 Electrolytic capacitor CD-560uF-400V...
Page 20
ATLANTIC 180/200 20/30 Le soudage peut provoquer des lésions à vous et aux autres. C’est pourquoi vous devez utiliser les moyens de protection appropriés pendant le soudage. Pour de plus amples informations, consultez le Guide de Protection de Sécurité pour Techniciens, qui répond aux exigences pour produits manufacturés en matière de prévention d’accidents.
à une inspection conformément aux contenus concernés. Si vous ne parvenez pas à identifier la panne, ou à résoudre le problème, veuillez contacter le distributeur ou le centre d’assistance de GALA GAR pour obtenir le support technique nécessaire. 2. INFORMATIONS GÉNÉRALES CONCERNANT LE PRODUIT La conception exclusive de la canalisation d’air et de la structure électrique de cette série de...
ATLANTIC 180/200 22/30 3. INFORMATIONS GÉNÉRALES CONCERNANT LES FONCTIONS Description des fonctions : Fonction d’amorçage Hot start : facilite et rend plus fiable l’amorçage de l’arc dans le soudage MMA. Fonction VRD : maintient la sécurité du technicien lorsque la machine est arrêtée.
Page 23
ATLANTIC 180/200 23/30 6. DESCRIPTION ET MODE DE FONCTIONNEMENT 1. LED de surchauffe : Il indique une surchauffe dans le poste de soudage. Le LED allumé nous signale que la température intérieure de la machine est trop élevée et qu’elle se trouve en mode de protection contre les surchauffes.
Page 24
ATLANTIC 180/200 24/30 1) Cette machine est fournie avec un câble primaire d’alimentation de courant. Brancher le câble d’alimentation de courant à la puissance nominale d'entrée. 2) Pour éviter l’oxydation, vous devez brancher de façon bien serrée le câble primaire sur la bonne prise.
Page 25
ATLANTIC 180/200 25/30 8. PRÉCAUTIONS Environnement de soudage 1) Le soudage doit être effectué dans un environnement sec avec un niveau d'humidité de 90% ou inférieur. 2) La température de l’environnement de travail doit se situer entre -10ºC et 40ºC.
Page 26
ATLANTIC 180/200 26/30 10. LOCALISATION DE PANNES L’opération suivante requiert des connaissances professionnelles suffisantes dans le domaine électrique ainsi que des connaissances complètes en matière de sécurité. Les techniciens doivent être en possession des certificats de qualification correspondants qui démontrent leurs capacités et leurs connaissances.
Page 27
ATLANTIC 180/200 27/30 LISTE DES PIÈCES DE RECHANGE À DES FINS D'ENTRETIEN Nº. Code du produit Nom du produit 10007251 IGBT-FGH40N60 10007253 IGBT-FGH60N60 10037794 IGBT-GD60SGK60T2S 10006272 Tube redresseur de courant WSAD92-02 10006248 Tube redresseur de courant D92-02 10006271 Tube redresseur de courant FFA60UP30DE 10005801 Condensateur électrolytique CD-470uF-400V...
Page 28
GALA GAR. The decision to repair or replace parts or supply a new appliance will depend on the criterion of GALA GAR. All replaced parts and products will be the property of GALA GAR.