Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Manual técnico de instrucciones
Technical instructions manual
Manuel technique d´instructions
KENNEDY
KENNEDY 140
KENNEDY 160
KENNEDY 200
Ref: 2229K140M
Ref: 2229K160M
Ref: 2229K200M

Publicité

Table des Matières
loading

Sommaire des Matières pour gala gar KENNEDY Serie

  • Page 1 Manual técnico de instrucciones Technical instructions manual Manuel technique d´instructions KENNEDY KENNEDY 140 Ref: 2229K140M KENNEDY 160 Ref: 2229K160M KENNEDY 200 Ref: 2229K200M...
  • Page 2: Table Des Matières

    Gala Gar ÍNDICE 1. SEGURIDAD ....................2 2. DESCRIPCIÓN GENERAL ................4 3. PARÁMETROS PRINCIPALES ..............5 4. DESCRIPCIÓN Y CONTROL DE FUNCIONAMIENTO .......6 5. MANEJO Y PUESTA A PUNTO DE LA INSTALACIÓN ........7 6. PRECAUCIÓN .....................8 7. MANTENIMIENTO ..................9 8. LOCALIZACIÓN DE AVERÍAS ..............10 DECLARACIÓN DE CONFORMIDAD...
  • Page 3: Seguridad

    Gala Gar 1. SEGURIDAD La soldadura es una operación peligrosa y puede ocasionar daños a usted mismo y a otras personas, por lo que deberá protegerse convenientemente a la hora de soldar. Para más información, le rogamos que consulte las normas de seguridad para operarios previstas en los requisitos de prevención de accidentes del fabricante.
  • Page 4 Gala Gar El manejo indebido puede ocasionar incendios o explosiones.  Las chispas de soldadura pueden provocar un incendio, por lo que le rogamos que no tenga materiales combustibles en las inmediaciones y preste mucha atención a los riesgos de incendio.
  • Page 5: Descripción General

    Gala Gar 2. DESCRIPCIÓN GENERAL  Tecnología inverter IGBT avanzada  La alta frecuencia de la tecnología inverter reduce considerablemente el volumen y el peso del equipo de soldadura.  La gran reducción en cuanto a pérdida magnética y de resistencia mejora claramente la eficacia de la soldadura y el efecto de ahorro energético.
  • Page 6: Parámetros Principales

    Gala Gar PARÁMETROS PRINCIPALES KENNEDY 200 MODELO KENNEDY 140 KENNEDY 160 AC230V±15% 50/60HZ Tensión nominal de entrada (V) Potencia nominal de entrada 7,11 Intensidad nominal de entrada 140A/25.6V 160A/26.5V 180A/27.2V Potencia nominal Rangos de corriente de 10~140A 10~160A 10~180A Tensión en vacío (V)
  • Page 7: Descripción Y Control De Funcionamiento

    Gala Gar 4. DESCRIPCIÓN Y CONTROL DE FUNCIONAMIENTO ● Panel de control delantero (véase la Figura 1) (1) "+" borne salida: Para conectar el portaelectrodo. (2) "-" borne salida: Para conectar la pinza de masa. (3) Selector corriente de soldadura: Para regular la corriente de salida.
  • Page 8: Manejo Y Puesta A Punto De La Instalación

    Gala Gar 5. MANEJO Y PUESTA A PUNTO DE LA INSTALACIÓN Nota: Le rogamos que instale la máquina siguiendo estrictamente los pasos siguientes. Apague el interruptor de alimentación corriente antes de llevar a cabo cualquier operación de conexión eléctrica. El grado de protección de esta máquina es IP21S, por lo que debe abstenerse de utilizarla en condiciones de lluvia.
  • Page 9: Precaución

    Gala Gar 5.3 Tabla de parámetros de soldadura (a efectos de referencia exclusivamente). Diámetro del electrodo en Corriente de soldadura Tensión de soldadura recomendada (A) recomendada (V) 20~60 20,8~22,4 44~84 21,76~23,36 60~100 22,4~24,0 80~120 23,2~24,8 108~148 23,32~24,92 140~180 24,6~27,2 180~220...
  • Page 10: Mantenimiento

    Gala Gar continuamente la corriente máxima de carga (consulte el factor de marcha correspondiente). Asegúrese de que la corriente de soldadura no supera la corriente máxima de carga. Las sobrecargas pueden acortar la vida útil de la máquina e incluso dañarla.
  • Page 11: Localización De Averías

    Gala Gar 8. LOCALIZACIÓN DE AVERÍAS La operación siguiente requiere un conocimiento profesional suficiente en el tema eléctrico y un completo conocimiento en materia de seguridad. Los operarios deben estar en posesión de correspondientes certificados cualificación demuestren sus habilidades y conocimientos. Antes de quitar la caja de protección exterior y dejar la máquina soldadora al...
  • Page 12: Declaration Of Conformity

    Gala Gar TABLE OF CONTENTS 1. SAFETY........................12 2. GENERAL DESCRIPTION..............…………….13 3. MAIN PARAMETERS................…………….14 4. OPERATION CONTROL AND DESCRIPTION............15 5. INSTALLATION DEBUGGING AND OPERATION..........16 6. CAUTION......................17 7. MAINTENANCE....................18 8. TROUBLESHOOTING..................19 DECLARATION OF CONFORMITY Hereby we declare that these machines are produced based on relative international standards and they conform to the international safety standard IEC974.
  • Page 13: Safety

    Gala Gar 1. SAFETY Welding is dangerous, and may cause damage to you and others, so take good protection when welding. For details, please refer to the operator safety guidelines in conformity with the accident prevention requirements of the manufacturer.
  • Page 14: General Description

    Gala Gar Hot workpiece may cause severe scalding.  Do not contact hot workpiece with bare hands.  Cooling is needed during continuous use of the welding torch. Magnetic fields affect cardiac pacemaker.  Pacemaker users should be away from the welding spot before medical consultation.
  • Page 15: Main Parameters

    Gala Gar 3. MAIN PARAMETERS KENNEDY 200 MODEL KENNEDY 140 KENNEDY 160 Rated input voltage (V) AC230V±15% 50/60H 7.11 Rated input power (KVA) Rated input current (A) 140A/25.6V 160A/26.5V 180A/27.2V Rated output 10~140A 10~160A 10~180A Welding current range (A) No-load voltage (V)
  • Page 16: Operation Control And Description

    Gala Gar 4. OPERATION CONTROL AND DESCRIPTION ● Front control panel (see Figure 1) 1. "+" output terminal: To connect the electrode holder. 2. "-" output terminal: To connect the work clamp. 3. Welding current knob: To adjust the output current.
  • Page 17: Installation Debugging And Operation

    Gala Gar 5. INSTALLATION DEBUGGING AND OPERATION Note: Please install the machine strictly according to the following steps. Turn off the power supply switch before any electric connection operation. The protection class of this machine is IP21S, so avoid using it in rain.
  • Page 18: Caution

    Gala Gar 5.3 Welding parameters table (for reference only) Electrode dia. (mm) Recommended welding Recommended welding current (A) voltage (V) 20~60 20.8~22.4 44~84 21.76~23.36 60~100 22.4~24.0 80~120 23.2~24.8 108~148 23.32~24.92 140~180 24.6~27.2 180~220 27.2~28.8 220~260 28.8~30.4 Note: This table is suitable for mild steel welding. For other materials, consult related materials and welding process for reference.
  • Page 19: Maintenance

    Gala Gar 2.4 A sudden halt may occur while the machine is of overload status. Under this circumstance, it is unnecessary to restart the machine. Remain the built-in fan working to lower the temperature inside the machine. 7. MAINTENANCE following...
  • Page 20 Gala Gar 9. TROUBLESHOOTING following operation requires sufficient professional knowledge on electric aspect and comprehensive safety knowledge. Operators should be holders of valid qualification certificates which can prove their skills and knowledge. Make sure the input cable of the machine is cut off from the electricity utility before uncovering the welding machine.
  • Page 21 Gala Gar TABLE DES MATIÈRES 1. SÉCURITÉ ....................21 2. DESCRIPTION GÉNÉRALE ..............23 3. PARAMÈTRES PRINCIPAUX..............24 4. DESCRIPTION ET CONTRÔLE DE FONCTIONNEMENT ......25 5. MANIEMENT ET RÉGLAGE DE L’INSTALLATION ........26 6. PRÉCAUTIONS ..................27 7. ENTRETIEN ....................28 8. LOCALISATION DE PANNES..............29 DÉCLARATION DE CONFORMITÉ...
  • Page 22: Sécurité

    Gala Gar 1. SÉCURITÉ Le soudage est une opération dangereuse qui peut provoquer des dommages à vous-même ou à d’autres personnes, raison pour laquelle vous devrez vous protéger lors du soudage. Pour plus d’informations, merci de consulter les normes de sécurité pour techniciens prévues dans les conditions de prévention des accidents du fabricant.
  • Page 23 Gala Gar Le mésusage peut provoquer des incendies ou des explosions.  Les projections de soudage peuvent provoquer un incendie, raison pour laquelle nous vous prions de ne pas avoir de matériaux combustibles à proximité et de prêter une grande attention aux risques d’incendie.
  • Page 24: Description Générale

    Gala Gar 2. DESCRIPTION GÉNÉRALE  Technologie avancée d'onduleur IGBT  La haute fréquence de la technologie à onduleur réduit considérablement le volume et le poids de l’équipement de soudage.  La grande diminution de la perte magnétique et de la résistance améliore nettement l’efficacité...
  • Page 25: Paramètres Principaux

    Gala Gar 3. PARAMÈTRES PRINCIPAUX MODÈLE KENNEDY 140 KENNEDY 160 KENNEDY 200 Tension nominale d’entrée (V) AC230V±15% 50/60HZ Puissance nominale d’entrée (KVA) 7,11 Intensité nominale d’entrée (A) Puissance nominale 140A/25.6V 160A/26.5V 180A/27.2V Plages de courant de soudage (A) 10~140A 10~160A 10~180A Tension à...
  • Page 26: Description Et Contrôle De Fonctionnement

    Gala Gar 4. DESCRIPTION ET CONTRÔLE DE FONCTIONNEMENT ● Panneau de contrôle avant (voir la Figure 1) 1. "+" borne de sortie: Pour brancher le porte-électrode. 2. "-" borne de sortie: Pour brancher la pince de masse. 3. Sélecteur du courant de soudage: Pour régler le courant de sortie.
  • Page 27: Maniement Et Réglage De L'installation

    Gala Gar 5. MANIEMENT ET RÉGLAGE DE L’INSTALLATION À noter : Nous vous demandons d’installer la machine en suivant rigoureusement les étapes suivantes. Éteignez l’interrupteur d'alimentation du courant avant d'effectuer toute opération de branchement électrique. Le degré de protection de cette machine est IP21S, vous devez donc vous abstenir de l’utiliser par conditions de pluie.
  • Page 28: Précautions

    Gala Gar 5.3 Tableau des paramètres de soudage (exclusivement à titre de référence). Diamètre de l’électrode Courant de soudage Tension de soudage en mm recommandé (A) recommandée (V) 20~60 20,8~22,4 44~84 21,76~23,36 60~100 22,4~24,0 80~120 23,2~24,8 108~148 23,32~24,92 140~180 24,6~27,2...
  • Page 29: Entretien

    Gala Gar 2.2 Il est interdit de souder avec une machine en état de surcharge. Nous vous demandons de vérifier continuellement le courant maximum de charge (consultez le facteur de marche correspondant). Assurez-vous que le courant de soudage ne dépasse pas le courant maximum de charge.
  • Page 30: Localisation De Pannes

    Gala Gar 8. LOCALISATION DE PANNES L’opération suivante requiert des connaissances professionnelles suffisantes dans domaine électrique ainsi connaissances complètes en matière de sécurité. Les techniciens doivent être en possession des certificats de qualification correspondants démontrent leurs capacités leurs connaissances. Avant d’enlever le boîtier de protection extérieur et laisser la machine à...
  • Page 31 FABRICACIÓN Y VENTA DE APARATOS DE SOLDADURA AUTÓGENA, ELÉCTRICA Y CONSTRUCCIONES ELECTROMECÁNICAS. MANUFACTURE AND SALE OF AUTOGENOUS, AND ELECTRIC WELDING APPLIANCES, AND ELECTROMECHANICAL CONSTRUCTIONS. FABRICATION ET VENTE D’APPAREILS DE SOUDAGE AUTOGÈNE, ÉLECTRIQUE ET CONSTRUCTIONS ÉLECTROMÉCANIQUES. CENTRAL: Jaime Ferrán, 19, nave 30 Apartado de Correos 5058 50080 ZARAGOZA Teléfono 976 47 34 10...

Ce manuel est également adapté pour:

Kennedy 140Kennedy 160Kennedy 2002229k140m2229k160m2229k200m

Table des Matières