PROGRAMMING
1)
PANEL OF OPERATING PARAMETERS
To program the operating parameters, press key
When the program number on display 2 begins blinking, you may enter the data by pressing
the keys
To switch to another parameter, use the
When you have programmed all the parameters, "lock" the program by pressing key
Explanation of the parameters:
1.1) Start time - delay. 0 to 99h59min
This timer function is used to delay the beginning of the firing cycle.
A Count-down before start time is displayed on 3.
Should you not wish to use this function, set the parameter at 0h 0 min and heating will begin
immediately (or use the
e
1
STAGE
st heating rate (Rampe
1.2) 1
The heating rate is the heat rise per unit time (rate of rise).
There are three positions:
- STOP position - the furnace stops heating.
This is only used when the next stage is at a Iower temperature.
- Position 1to 15°/mn
Heating is regulated and will not rise above the programmed value. However, it may be
lower than that value, especially in the higher temperature ranges or if the muffle is
weIl Ioaded.
- ''FULL'' Position
This position corresponds to the maximum furnace out put. Here,
the heat rise rate is no longer regulated.
1.3) Température 0 to 1200°C
Temperature setting for the 1st stage.
1.4) Hold time 0 to 240 mn
Hold time for the temperature of the 1st stage.
key.
.
key after pressing the
N° 1)
22
PROGRAMIX 50/100
touch control)
again.