Adjustment mode
1. Take the alignment of the rotary laser into account when performing adjustment work.
Always adjust all the axes.
2. Switch the device to adjustment mode:
Switch off the rotary laser and switch it on again while holding the auto/slope button. Press
and hold the auto/slope button until the x-axis indicator starts to flash on the display. Then
you can release the auto/slope button.
The x-axis indicator flashes first in horizontal mode (X/Y axis). You can switch between x and
y-axis using the X/Y button on the rotary laser.
Only the Y-axis indicator is shown in vertical mode (z-axis).
3. Correcting the adjustment:
Using the Plus/Minus buttons on the rotary laser, you can move the laser away from its current
position to the level of reference point A2. The laser only changes its position by pressing the
buttons several times.
4. Completing the adjustment:
Cancel:
Switch the rotary laser off (via the ON/OFF button) to reject all adjustment
settings and restore the previous status.
Save:
Pressing the auto/slope button saves the new adjustment settings.
Positioning:
The laser can be rotated by pressing the positioning buttons on
the remote control.
Regularly check the adjustment before use, after
!
transport and after extended periods of storage.
Always make sure to control all axes.
Quadrum DigiPlus
Z
X- / Y- /
Z-Axis
Y
X
23
GB