6.

Technical Data

Technical data
Item No.
Housing
Category
Gas device type
Total nominal heat load
Connection value for city gas
Connection value for liquefied gas
Connection value for natural gas
Gas connection diameter
Burners
Control range
Subject to technical changes without prior notice!
7.

Conversion to a Different Gas Type

Observe the safety instructions, refer to page 18, chapter 1.
D For conversion to different gas types, use original nozzles only.
. After conversion to a different gas type and maintenance works:
− Check all gas-bearing components for leak tightness (leakage spray),
− attach a label stating gas type and gas pressure (mbar) to the gas range.
. Read off the data required for conversion from the nozzle table/overview, refer to page 25,
chapter 7.1
24 / 68
Two-burner gas range
(Type 800-...)
975516, 976105,
884076, MA603000,
MA603010, VP603000,
VP603010
Stainless steel
Refer to page 25,
chapter 7.1
A1
12 kW
3
3,10 m
/h
0,93 kg/h
3
1,27 m
/h
G 1/2 A
1 x 5 kW; 1 x 7 kw
Large and small flame
Four-burner gas
range (Type 800-...)
975524, 884077
MA603100, VP603100
Stainless steel
Refer to page 25,
chapter 7.1
A1
24 kW
3
6,20 m
/h
1,86 kg/h
3
2,54 m
/h
G 1/2 A
2 x 5 kW; 2 x 7 kW
Large and small flame

Publicité