Nozzle type
Nozzle type
Nozzle type
Gas type
Gas type
Gas type
SE - Category: III
City gas ab
Primary pressure 8 mbar
(SE)
Natural gas H
Primary pressure 20 mbar
(SE)
Liquid gas B/P
Primary pressure 30 mbar
(SE)
DK - Category: III
City gas e
Primary pressure 8 mbar
(DK)
Natural gas H
Primary pressure 20 mbar
(DK)
Liquid gas B/P
Primary pressure 30 mbar
(DK)
7.2
Outer nozzle replacement
Outer nozzle
Refer to page 27,
chapter 7.2
1ab 2H 3B/P
Burner
D = ø 3,10 mm
E = ø 4,00 mm
Burner
D = ø 1,65 mm
E = ø 2,00 mm
Burner
D = ø 1,10 mm
E = ø 1,35 mm
1e 2H 3B/P
Burner
D = ø 3,10 mm
E = ø 4,00 mm
Burner
D = ø 1,65 mm
E = ø 2,00 mm
Burner
D = ø 1,10 mm
E = ø 1,35 mm
Threaded pin
Connector
Outer nozzle
Reduction nozzle
For settings, refer to
page 28, chapter 7.3
Burner
D = ø 1,60 mm
E = ø 2,20 mm
Burner
D = ø 0,85 mm
E = ø 1,05 mm
Burner
D = ø 0,55 mm
E = ø 0,65 mm
Burner
D = ø 1,60 mm
E = ø 2,20 mm
Burner
D = ø 0,85 mm
E = ø 1,05 mm
Burner
D = ø 0,55 mm
E = ø 0,65 mm
. Loosen the threaded pin until the connector
can be withdrawn.
. Withdraw the connector.
. Replace the outer nozzle, refer to the data
stated in the table on page 25, chapter 7.1
. Insert the connector down to the limit stop
and secure it by means of the threaded pin.
. Check all gas-bearing components for the
leak tightness.
en
Pilot burner nozzle
For pilot burner nozzle
replacement, refer to
page 28, chapter 7.4
Burner
D = ø 0,60 mm
E = ø 0,60 mm
Burner
D = ø 0,32 mm
E = ø 0,32 mm
Burner
D = ø 0,18 mm
E = ø 0,18 mm
Burner
D = ø 0,60 mm
E = ø 0,60 mm
Burner
D = ø 0,32 mm
E = ø 0,32 mm
Burner
D = ø 0,18 mm
E = ø 0,18 mm
27 / 68