5.
Malfunctions and Rectification
Should malfunctions occur with the gas range, please check them with the help of the following
table:
Malfunction
The pilot light cannot be lit.
The pilot light is extin
guished upon the gas gov
ernor's release.
Should you not be able to rectify the malfunction,
- Press the gas governor in and turn it to the "OFF" position (symbol
- Close the gas tap.
- do not open the housing,
- inform the customer service.
Thermal
element
Pilot burner
Cause
The gas tap is closed.
The service valve is closed.
The pilot burner is contamin
ated.
The thermal element is contam
inated.
The gas governor was not
pressed in long enough.
The thermal element is defect
ive.
Open
Close
. Remove the pilot burner cover.
. Remove any residues from the pilot light and
the thermal elements by means of a fine
wire brush.
Do not use any wet or humid cloths
for cleaning!
During the cleaning process, assure that
the pilot burner and the nozzle are not con
taminated / blocked!
. Attach the pilot burner cover.
Rectification
Open the gas tap.
Open the service valve.
Clean the pilot burner.
Clean the thermal element.
Keep the gas governor pressed
for approx. 5 - 10 seconds to
assure the thermal elements
sufficient heating and avoid an
interruption of the gas supply.
inform the customer service.