Load Distribution; Functional Description - Columbus McKinnon HTS-E PROLINE Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Standard Lifting Table HTS-E PROLINE
English

Load distribution

Do not exceed the carrying capacity as per data sheet (nameplate).
The lifting table is designed for equally distributed load. With other distribution of load, please refer to the below
stated pictures.
A
equal distributed
one-sided load distributed
surface load
on ½ platform length
100 %
max.50% of A
1)
Rolling load without fixing devices must be secured appropriately by the operator (for example by wedges,
lashing straps ...)
Before taking into operation, a competent person must check installation and electric connection.
After erection and concrete pouring a trial run with and without load has to be effected after the
concrete has set.
The results have to be noted in the test book.
Electric installation
Trained experts may only execute the electric connection or repair on electric parts.
Observe the safety regulations and standards of electrical engineering
Works on the electric installation may only be executed with clear power supply.
Daily examinations:
functional switch up/down
safety contact rail
lift limit switch
emergency stop main switch
pressure relief valve
control
Tightness of the hydraulic system. (during a period of 10 minutes no lowering must be noted!).
load bearing parts of the structure.
the load carrying medium
The lifting table should be given a thorough examination by a competent person at least once a year.
The results have to be noted in the test book.
Always ensure the maintenance intervals are adhered to.
Only use original accessories and spare parts; otherwise, safe function is not guaranteed.

Functional Description:

The hydraulic lifting table is a lifting platform with hydraulic drive.
One or two hydraulic cylinders via a scissors system lift the platform.
Actuation is effected by means of a hydraulic pump with three-phase AC motor.
Lowering after having opened the 2/2-way poppet valve.
A mounted-in micro-flow control valve regulates the lowering speed.
Hose break valves are mounted in the hydraulic cylinders.
The hydraulic aggregate is equipped with a safety valve.
The lifting table is equipped with an electric contactor control and thermal motor protection switch.
Supporting devices for maintenance works are fixed to the scissors in hinged design.
Under the platform, a safety contact rail is mounted.
When operating this contact rail, the lowering movement is interrupted.
technische Änderungen vorbehalten
B
C
one-sided load distributed on
½ platform width
max.30% of A
design changes under reserve
F 06.08.109
D
edge load distributed on ½ platform
length and on ½ platform width
max.30% of A
changements techniques sous réserve
E
1)
rolling load
centric max. 60% of A
any load max. 30% of A
18

Publicité

Table des Matières
loading