Connecting The Device - Atlantic Galapagos Notice D'utilisation Et D'installation

Radiateur chaleur douce à inertie
Masquer les pouces Voir aussi pour Galapagos:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection rules and regulations
- The device must be supplied with 230V single-phase current at 50Hz.
- The device's power supply must be directly connected to the main supply after the circuit breaker without any interme-
diate switch.
- The device's power cable must be connected to the main supply via a connection box. In damp areas, such as bathrooms
and kitchens, the connection box must be installed at least 25cm above the floor.
- An Earth connection is prohibited. Do not connect the pilot wire (black wire) to Earth.
- The installation must be fitted with an all-pole cut-off switch with a contact opening distance of at least 3mm.
- If the power cable is damaged, it must only be replaced by an electrician.
- If you are using the pilot wire and it is protected by a 30mA differential (e.g.: bathroom use), the pilot wire's power supply must
also be protected on this differential.
Wiring diagram for the device
- Cut off the power supply and connect the wires as shown in the following diagram :
You can connect the pilot wire if your home is equipped with a programming unit or controller.
In this case, make the following checks according the selected mode (Comfort, Eco, etc.) to that the programming instruc-
tions are being transmitted correctly:
COMFORT
Signal to be
transmitted
Measurement
between the
0 Volt
pilot wire and
neutral
C
ONNECTING THE DEVICE
Panel heater cable
Phase=brown
Neutral=blue
Pilot wire=Black
1st case: only one heater
2nd case: Slave heater
3rd case: Master heater
ECO
FROST
-115 Volts
230 Volt
negative
PHASE
NEUTRAL
Three possible cases
The pilot wire end is insulated
and not further connected
To the appliance with cassette or
programming unit.
To pilot wire of an electronically
controlled appliance
SWITCH-OFF OF
HEATING AND POWER
CUT-OFF
+115 Volts positive
22
Electricity
grid
COMFORT -1°C COMFORT -2°C
5'
3''
230 Volts
for 3 s
-
5'
7''
230 volts
for 7 s

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Table des Matières