1
B
C

3) Connecting the device

- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using a 3-wire
cable (Brown=Phase, Blue=Neutral, Black=Pilot
wire), through a connecting box. In damp premi-
ses, such as bathrooms and kitchens, install the
connecting box at least 25 cm from the ground.
- The installation must be equipped with a shutting-
off device in all poles having a distance of opening
of contact of at least 3 mm.
- Ground connection is forbidden.
Do not connect the pilot wire (black) to ground.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified elec-
trician using special tools.
- If a device pilots or is piloted by a 30mA differential (e.g. bathroom), the pilot wire supply must be
protected on this differential.
4) How to fit the 2 pegs ?
1/Select the locations from the 4 to 6 available, depending on your machine's output.
2/Push the peg into the hole in the channel.
3/Screw tight.
1
Power (W)
600 +1000
750 +1000
900 +1000
2
A
4
Measurement
Measurement
(A)
(B)
1108
1433
503
1758
3
5
Panel heater cable
Pilot wire=Black
1st case: only one heater
2nd case: multiple heaters
2
10
Measurement
(C)
277
262
262
Note: The pins
supplied with the
device are of the
standard type.
In case of a parti-
cular stand, use
appropriate pins.
Live=brown
LIVE
NEUTRAL
Neutral=blue
Two possible cases
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
3
Electricity
grid
220-240V insulated cable
2

Publicité

Table des Matières
loading

Table des Matières