3) Connecting the device
- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using a 3-wire cable
(Brown=Phase, Blue=Neutral, Black=Pilot wire), through
a connecting box. In damp premises, such as bathrooms
and kitchens, install the connecting box at least 25cm
from the ground.
- The installation must be equipped with a shutting-off devi-
ce in all poles having a distance of opening of contact of
at least 3mm.
- Ground connection is forbidden.
Do not connect the pilot wire of the device (black) to the earth.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified electrician
using special tools.
- If a device pilots or is piloted by a 30mA differential (e.g. bathroom), the pilot wire supply must be pro-
tected on this differential.
4) How to connect the mixed version to the water system ?
For the connection of hot water, the mixed version comprises 2 threaded ports 1/2 gas 15/21 F situated at
the base, as well as a purge with adjustable spray on the top on the right
There are two types of connections:
Type 1: Connection for water at the base.
Type 2: Connection for water on the right hand side.
- For type 1, place two 90° standard elbows on the T connections at the back of the device (elbows not
supplied). Position the two extensions supplied on the 90° elbows.
- For type 2, place two 90° standard elbows on the T connections at the back of the device (elbows not
supplied). Position a 50mm extension (standard on the market) on the bottom elbow (extension not sup-
plied).
Follow the flow direction as well as the figures stipulated on the diagram below.
TYPE 1:
CONNECTION AT
THE BASE