Perform maintenance on the following components:
• Shower head (see
• Filters (see
• Non-return valves (see
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
Removing the stainless steel housing
Some maintenance work requires that the stainless steel housing be removed.
15.1 Only when the water connection is from the top:
Close the flow volume regulator.
a: closed
b: open
15.2 Only when the water connection is from the top:
Trigger the valve.
Release the connecting hoses for hot and cold water from the water volume
regulators.
15.3 Loosen the screws on the stainless steel housing.
☞
Never let the stainless steel housing hang by the connecting hoses.
15.4 Unhinge the stainless steel housing.
15.5 Only when the water connection is from the rear:
Close the flow volume regulators (see
15.6 Only when the water connection is from the rear:
Trigger the valve.
Release the connecting hoses for hot and cold water from the water volume
regulators.
16. Replacing the Grit Filters
Filters in water volume regulator
16.1 Remove the stainless steel housing (see
16.2 Unscrew the screw plugs (a) on the water volume regulator.
16.3 Replace the grit filters (b).
☞
Important!
Be careful to insert the grit filters the right way round.
16.4 Reassemble in the reverse order.
Chapter
18.)
Chapter
16.)
Chapter
17.)
Work step
15.1).
Chapter
15.).
- 8 -